自体髂骨嵴移位重建掌骨头的解剖学研究
摘要点击次数: 1871   全文下载次数: 1069   投稿时间:2017-05-25    
作者Author单位AddressE-Mail
缪道一 MIAO Dao-yi 温州医科大学附属第三医院 瑞安市人民医院显微外科, 浙江 瑞安 325200 Department of Microsurgery, the Third Affiliated Hospital of Wenzhou Medical University, Ruian 325200, Zhejiang, China  
张凌洲 ZHANG Ling-zhou 温州医科大学附属第三医院 瑞安市人民医院显微外科, 浙江 瑞安 325200 Department of Microsurgery, the Third Affiliated Hospital of Wenzhou Medical University, Ruian 325200, Zhejiang, China 414563966@qq.com 
李慧辉 LI Hui-hui 温州医科大学附属第三医院 瑞安市人民医院显微外科, 浙江 瑞安 325200 Department of Microsurgery, the Third Affiliated Hospital of Wenzhou Medical University, Ruian 325200, Zhejiang, China  
杨国敬 YANG Guo-jing 温州医科大学附属第三医院 瑞安市人民医院显微外科, 浙江 瑞安 325200 Department of Microsurgery, the Third Affiliated Hospital of Wenzhou Medical University, Ruian 325200, Zhejiang, China  
期刊信息:《中国骨伤》2017年,第30卷,第11期,第1018-1022页
DOI:10.3969/j.issn.1003-0034.2017.11.010
基金项目:
中文摘要:

目的:探讨髂骨嵴与掌骨头相似性,为髂骨嵴移位重建手部掌骨头提供解剖学基础。

方法:16侧上肢标本,10例骨盆标本,解剖观察第2、3、4、5掌骨头及髂骨嵴形态结构特点,测量掌骨头弧高、关节面弧长、掌背径、尺桡径和髂骨嵴弧高、弧长、内外径。将所得到的数据进行统计分析,比较各掌骨头与髂骨嵴在形态、结构特点、弧长及各径线长度相似度。

结果:第2掌骨头弧长22.040(21.425,23.085) mm,掌背径(14.034±0.465) mm,弧高4.185(4.113,4.598) mm,尺桡径(12.227±0.414) mm。第3掌骨头弧长23.430(22.743,24.153) mm,掌背径(14.316±0.430) mm,弧高4.235(4.170,4.670) mm,尺桡径(12.382±0.425) mm。第4掌骨头弧长21.960(21.245,22.285) mm,掌背径(12.382±0.288) mm,弧高4.125(4.030,4.305) mm,尺桡径(11.991±0.362) mm。第5掌骨头弧长20.030(19.668,20.148) mm,掌背径(11.807±0.358) mm,弧高4.015(3.880,4.205) mm,尺桡径(11.659±0.399) mm。髂骨嵴弧长(22.930±0.701) mm,内外径14.350(13.660,14.739) mm,弧高(4.520±0.184) mm。髂骨嵴内外径与第2掌骨头掌背径差异无统计学意义(Z=-1.242,P>0.05),髂骨嵴内外径与第3掌骨头掌背径差异有统计学意义(Z=-2.835,P<0.05),髂骨嵴内外径与第4、5掌骨头掌背径差异有统计学意义(Z值分别为-5.094、-5.095,P<0.05);髂骨嵴弧长与第2、4、5掌骨头弧长差异均有统计学意义(t值分别为1.190、-4.909、-13.791,P<0.05),髂骨嵴弧长与第3掌骨头弧长差异无统计学意义(Z=-1.704,P>0.05);髂骨嵴弧高与第2、3掌骨头弧高差异无统计学意义(Z值分别为-1.815、-1.386,P>0.05),髂骨嵴弧高与第4、5掌骨头弧高差异有统计学意义(分别对应Z=-3.152,t=-5.639,P<0.05)。

结论:自体髂骨嵴与掌骨头在解剖学上有一定相似性,能够成为掌骨头移植的合适供体。
【关键词】髂骨嵴  掌指关节  移位  应用解剖
 
Anatomical study on the reconstruction of the metacarpal bone with autogenous iliac crest grafting
ABSTRACT  

Objective: To explore the similarity between the iliac crest and the metacarpal bone,so as to provide an anatomical basis for the reconstruction of the metacarpal bone of the hand with the iliac crest grafting.

Methods: There are 16 upper limb specimens and 10 pelvic specimens. The morphological features of the second,third,fourth and 5th metacarpal bones and iliac crest were observed. The following indexes were measured:arc height and length of metacarpal head articular surface,volar-dorsal metacarpal diameter,ulnoradial diamater,arc height and length of iliac crest,and inner and outer diameter. The obtained data were statistically analyzed to compare the morphological,structural features,arc length and diameter length of each metacarpal bone and iliac crest.

Results: The arc length of the second metacarpal head,volar-dorsal metacarpal diameter,arc height,and the ulnoradial diameter are 22.040(21.425,23.085) mm,(14.034±0.465) mm,4.185 (4.113,4.598) mm,and (12.227±0.414) mm respectively. The arc length of the third metacarpal head,volar-dorsal metacarpal diameter,arc height,and the ulnoradial diameter are 23.430(22.743,24.153)mm,(14.316±0.430) mm,4.235(4.170,4.670) mm,and (12.382±0.425) mm respectively. The arc length of the fourth metacarpal head,volar-dorsal metacarpal diameter,arc height,and the ulnoradial diameter are 21.960 (21.245,22.285) mm,(12.382±0.288) mm,4.125 (4.030,4.305) mm,and (11.991±0.362) mm respectively. The arc length of the fifth metacarpal head,volar-dorsal metacarpal diameter,arc height,and the ulnoradial diameter are 20.030 (19.668,20.148) mm,(11.807±0.358) mm,4.015(3.880,4.205) mm,and (11.659±0.399) mm respectively. The inner and outer diameter of the iliac crest is 14.350 (13.660,14.739) mm,and the arc length and height are (22.930±0.701) mm and (4.520±0.184) mm respectively. The difference between the volar-dorsal metacarpal diameter of the second metacarpal head and the inner and outer diameter of the iliac crest has no significant;while the volar-dorsal metacarpal diameter of the third,fourth and fifth metacarpal heads are apparently longer and shorter than the inner and outer diameter of the iliac crest,respectively. The differences are statistically significant. The differences between arc length of the iliac crest and arc length of the second,fourth and fifth metacarpl head are statistically significant. However,the difference of arc length between the third metacarpal head and the ilium,as well as the difference of arc height between the second and third metacarpal heads and the iliac crest have no statistical significances,while the arc height of the fourth and fifth metacarpal heads are obviously smaller than that of the iliac crest.

Conclusion: Autologous iliac crest is similar with metacarpal bone in anatomy,which might be a suitable donor for metacarpal bone transplantation.
KEY WORDS  Iliac crest  Metacarpophalangeal joint  Displacement  Applied anatomy
 
引用本文,请按以下格式著录参考文献:
中文格式:缪道一,张凌洲,李慧辉,杨国敬.自体髂骨嵴移位重建掌骨头的解剖学研究[J].中国骨伤,2017,30(11):1018~1022
英文格式:MIAO Dao-yi,ZHANG Ling-zhou,LI Hui-hui,YANG Guo-jing.Anatomical study on the reconstruction of the metacarpal bone with autogenous iliac crest grafting[J].zhongguo gu shang / China J Orthop Trauma ,2017,30(11):1018~1022
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号