穿针滑动固定家兔胫骨实验性骨折愈合过程断端位移测试 |
摘要点击次数: 1967
全文下载次数: 1295
投稿时间:2000-12-11
|
作者 | Author | 单位 | Address | E-Mail |
钟红刚 |
ZHONG Hong gang |
中国中医研究院骨伤科研究所,北京100700 |
Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700 |
|
赵宏普 |
ZHAO Hong pu |
中国中医研究院骨伤科研究所,北京100700 |
Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700 |
|
宋跃 |
SONG Yue |
中国中医研究院骨伤科研究所,北京100700 |
Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700 |
|
赵勇 |
|
中国中医研究院骨伤科研究所,北京100700 |
Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700 |
|
孟和 |
|
中国中医研究院骨伤科研究所,北京100700 |
Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700 |
|
|
期刊信息:《中国骨伤》2001年,第14卷,第10期,第604-605页 |
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz |
基金项目: |
|
中文摘要:
目的:研究骨折愈合过程中断端微动。
方法:采用穿针滑动固定家兔胫骨实验性骨折治疗动物模型,手术截骨造成横断骨折,骨折线位于胫骨中部,采用自制滑动固定器4针固定,针径15mm;采用霍尔元件磁场传感器测量位移。
结果:术后1天断端最大位移278±122微米,2周时为190±91微米,3周时为70±35微米,4周时为54±25微米。
结论:所采用的骨折治疗模型具有对骨折断端生物力学环境的测控能力,骨折断端微动的大小能反映骨折愈合的早期进程。 |
【关键词】骨折 骨折固定术 生物力学 |
|
Measurement of the displacement of the fracture site in the healing progress of the rabbit tibia fixed by pins with sliding fixator |
|
ABSTRACT
Objective:To investigate the micro movement of the fracture site
Methods: Fracture of rabbit tibia was fixed by pins with sliding fixator.The transverse fracture line at middle portion of the tibia was produced by osteotomy;the fracture was then fixed with 4 pins on the sliding fixator and the diameter of pins was 1 5mm;displacement was measured by Hauer magnetic field sensor.
Results:The displacement of the fracture site was 278±122 microns at the first day after operation,190±91 microns at 2 weeks,70±35 microns at 3 weeks and 54±25 microns at 4 weeks.
Conclusion:The fracture model enabled us to survey the biomechanical environment of the fracture site and the displacement of fracture site can reflect the healing progress of fracture. |