骨科机器人辅助下F钉技术与倒三角平行钉治疗不稳定型股骨颈骨折的疗效比较
Hits: 1121   Download times: 354   Received:April 25, 2023    
作者Author单位UnitE-Mail
赵兴龙 ZHAO Xing-long 甘肃中医药大学, 甘肃 兰州 730000 Gansu University of Chinese Medicine, Lanzhou 730000, Gansu, China  
申建军 SHEN Jian-jun 甘肃省中医院, 甘肃 兰州 730050 Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou 730050, Gansu, China shjjun2008@163.com 
冯康虎 FENG Kang-hu 甘肃省中医院, 甘肃 兰州 730050 Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou 730050, Gansu, China  
陈志伟 CHEN Zhi-wei 甘肃省中医院, 甘肃 兰州 730050 Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou 730050, Gansu, China  
司元龙 SI Yuan-long 甘肃省中医院, 甘肃 兰州 730050 Gansu Provincial Hospital of Traditional Chinese Medicine, Lanzhou 730050, Gansu, China  
张璇 ZHANG Xuan 甘肃中医药大学, 甘肃 兰州 730000 Gansu University of Chinese Medicine, Lanzhou 730000, Gansu, China  
王冠德 WANG Guan-de 甘肃中医药大学, 甘肃 兰州 730000 Gansu University of Chinese Medicine, Lanzhou 730000, Gansu, China  
海祥 HAI Xiang 甘肃中医药大学, 甘肃 兰州 730000 Gansu University of Chinese Medicine, Lanzhou 730000, Gansu, China  
期刊信息:《中国骨伤》2024年37卷,第2期,第129-134页
DOI:10.12200/j.issn.1003-0034.20221191
基金项目:甘肃省卫生行业科研计划项目(编号:GSWSKY-2021-35)


目的:比较天玑机器人辅助下F钉技术与倒三角平行钉内固定治疗不稳定型股骨颈骨折的临床疗效。

方法:回顾性分析2019年12月至2021年4月运用天玑手术机器人经皮置入空心螺钉内固定治疗不稳定型股骨颈骨折72例,其中37例采用F钉内固定,男16例,女21例;年龄47~64(53.87±5.28)岁;依据Pauwels损伤分型,Ⅰ型1例,Ⅱ型19例,Ⅲ型17例;合并内科疾病8例;摔伤17例,车祸伤8例,高处坠落伤12例;受伤至手术时间29~49(35.00±7.34) h。另35例采用倒三角平行钉内固定,男13例,女22例;年龄46~63(52.36±5.05)岁;依据Pauwels损伤分型,Ⅰ型2例,Ⅱ型21例,Ⅲ型12例;合并内科疾病6例;摔伤15例,车祸伤9例,高处坠落伤11例;受伤至手术时间30~45(33.00±6.83) h。观察比较两组术中出血量、手术时间、术中透视次数、随访时间、骨折愈合时间及术后并发症,分别于术后6、12个月采用Harris评分对髋关节功能进行评价。

结果:两组患者均定期随访,时间12~16个月。两组手术时间、术中出血量,术中透视次数比较,差异无统计学意义(P>0.05);F钉内固定组在骨折愈合时间、Harris评分方面均优于倒三角平行钉内固定组(P<0.05)。F钉内固定组出现1例股骨颈短缩;倒三角内固定组出现1例不愈合,1例退钉,1例下肢深静脉血栓形成;F钉内固定组并发症发生率低于倒三角平行钉内固定组(P<0.05)。

结论:运用天玑机器人导航定位系统经皮空心螺钉F钉技术治疗不稳定性股骨颈骨折患者是安全有效的治疗方式,能够显著减缩短骨折愈合时间、减低术后并发症的发生率并明显改善髋关节的功能,提高患者生活质量。
[关键词]:股骨颈骨折  生物力学  骨科机器人  F钉技术
 
Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures
Abstract:

Objective To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures.

Methods A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021. Among them, 37 patients were treated with F screw internal fixation, including 16 males and 21 females, aged 47 to 64 years old with an average of (53.87±5.28) years old;According to Pauwels classification, there were 1 case of type Ⅰ, 19 cases of type Ⅱ, 17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling, 8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of (35.00±7.34) hours. Another 35 cases used internal fixation with an inverted triangle parallel nail, including 13 males and 22 females with an average age of 46 to 63 years old (52.36±5.05) years old;According to the Pauwels injury classification:there were 2 cases of type Ⅰ, 21 cases of type Ⅱ, 12 cases of type Ⅲ;6 cases of medical diseases, 15 cases of falling injury, 9 cases of traffic accident, 11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of (33.00±6.83) h. The intraoperative blood loss, operation time, intraoperative fluoroscopy times, follow-up time, fracture healing time, postoperative complications were observed and compared between the two groups. The hip joint function was evaluated by Harris score at 6 months and 12 months after operation.

Results There was no significant difference in operation time, intraoperative blood loss, intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05). Both groups were followed up regularly, and the follow-up time was 12 to 16 months. The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group (P<0.05). There was 1 case of femoral neck shortening in the F screw internal fixation group, 1 case of nonunion, 1 case of nail withdrawal, and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group. The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05).

Conclusion Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures. It can significantly shorten the fracture healing time, reduce the incidence of postoperative complications, significantly improve hip joint function, and improve the quality of life.
KEYWORDS:Femoral neck fracture  Biomechanics  Orthopaedic robot  F screw technique
 
引用本文,请按以下格式著录参考文献:
中文格式:赵兴龙,申建军,冯康虎,陈志伟,司元龙,张璇,王冠德,海祥.骨科机器人辅助下F钉技术与倒三角平行钉治疗不稳定型股骨颈骨折的疗效比较[J].中国骨伤,2024,37(2):129~134
英文格式:ZHAO Xing-long,SHEN Jian-jun,FENG Kang-hu,CHEN Zhi-wei,SI Yuan-long,ZHANG Xuan,WANG Guan-de,HAI Xiang.Comparison of the efficacy of TiRobot orthopaedic robot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures[J].zhongguo gu shang / China J Orthop Trauma ,2024,37(2):129~134