Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
枢椎后路峡部螺钉固定的相关影像学测量
Hits: 1321   Download times: 528   Received:October 21, 2021    
作者Author单位UnitE-Mail
廖旭昱 LIAO Xu-yu 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo 315040, Zhejiang, China liaoxuyumehf@sina.com 
马维虎 MA Wei-hu 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo 315040, Zhejiang, China  
周雷杰 ZHOU Lei-jie 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo 315040, Zhejiang, China  
刘观燚 LIU Guan-yi 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo 315040, Zhejiang, China  
韩金明 HAN Jin-ming 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, Ningbo No. 6 Hospital, Ningbo 315040, Zhejiang, China  
期刊信息:《中国骨伤》2022年35卷,第8期,第779-784页
DOI:10.12200/j.issn.1003-0034.2022.08.015
基金项目:浙江省医药卫生科技项目(面上项目编号:2021455993)


目的:通过CT测量探讨枢椎峡部螺钉固定技术的安全性和可行性。

方法:收集2016年1月至2019年12月进行全颈椎CT检查的137例结构完整的上颈椎CT数据,其中男71例,女66例;年龄22~65(41.8±17.4)岁。通过Mimics19.0软件测量峡部螺钉技术相关的解剖学数据,包括峡部宽度、峡部垂直长度、峡部垂直高度、峡部螺钉通道长度、峡部螺钉通道头倾角度。并分析各项指标之间的相关性。

结果:枢椎峡部宽度(9.05±1.63) mm,垂直长度(11.21±1.43) mm,垂直高度(17.53±2.93) mm。螺钉通道长度为(19.07±3.20) mm。峡部螺钉通道长度>14 mm的占94.53%,14~16 mm的占82.12%,16~18 mm的占63.14%,18~20 mm的占39.78%。螺钉通道的头倾角度为30°~68°,平均(46.06±8.06)°。螺钉通道长度和头倾角度呈高度正相关(r=0.965,P=0.000)。峡部垂直长度和螺钉通道长度,峡部垂直长度和螺钉的头倾角度之间都呈轻度正相关(r=0.240,P=0.000;r=0.163,P=0.007)。峡部宽度和螺钉通道长度,峡部宽度和螺钉通道的头倾角度之间都呈中度负相关(r=-0.333,P=0.000;r=-0.380,P=0.000)。

结论:进行枢椎后路峡部螺钉固定安全、可靠,比枢椎后路椎弓根螺钉固定具有更大的适用范围,可以作为椎弓根螺钉的替代选择。
[关键词]:枢椎  椎弓峡部  骨螺钉  影像学  测量
 
Imaging measurement for the posterior pars interarticularis screw fixation on axis
Abstract:

Objective: To explore the safety and feasibility of posterior pars interarticularis screw fixation on axis by CT measurement.

Methods: The CT data of 137 patients with complete upper cervical spine who underwent full cervical spine CT examination from January 2016 to December 2019 were collected, including 71 males and 66 females, aged from 22 to 65 years old with an average of (41.8±17.4) years old. Mimics 19.0 software was used to measure anatomical data related to the pars interarticularis screw, including the pars width, pars vertical length, pars vertical height, length of pars screw trajectory, upward inclination angle of pars screw trajectory. And the correlation between each index was analyzed.

Results: The axis pars has an average width of(9.05±1.63) mm, an average vertical length of(11.21±1.43) mm, and an average vertical height of (17.53±2.93) mm. The mean length of pars screw trajectory was(19.07±3.20) mm. Regarding to the length of pars screw trajectory, 94.53% of pars measured more than 14 mm, 82.12% of pars measured at 14-16 mm, 63.14% of pars measured at 16-18 mm, 39.78% of pars measured at 18-20 mm. The upward inclination angle of pars screw was 30°-68° with an average of(46.06±8.06) °. There was a highly positive correlation between the length of screw trajectory and upward inclination angle(r=0.965, P=0.000). The vertical length of pars was weakly positively correlated with length of screw trajectory and upward inclination angle(r=0.240, P=0.000;r=0.163, P=0.007). Pars width was moderately negative correlated with length of scrwe trajectory and upward inclination angle(r=-0.333, P=0.000;r=-0.380, P=0.000).

Conclusion: The posterior pars interarticularis screw fixation is safe and reliable. It has a more wider applicability than pedicle screw fixation and can be used as an alternative to pedicle screws.
KEYWORDS:Axis  Pars interarticularis  Bone screws  Imaging  Measurement
 
引用本文,请按以下格式著录参考文献:
中文格式:廖旭昱,马维虎,周雷杰,刘观燚,韩金明.枢椎后路峡部螺钉固定的相关影像学测量[J].中国骨伤,2022,35(8):779~784
英文格式:LIAO Xu-yu,MA Wei-hu,ZHOU Lei-jie,LIU Guan-yi,HAN Jin-ming.Imaging measurement for the posterior pars interarticularis screw fixation on axis[J].zhongguo gu shang / China J Orthop Trauma ,2022,35(8):779~784
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com