Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
下颈椎前路椎弓根螺钉固定系统的设计与运用
Hits: 2682   Download times: 1211   Received:August 20, 2013    
作者Author单位UnitE-Mail
赵刘军 ZHAO Liu-jun 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China zhaoliujun555@sina.com 
徐荣明 XU Rong-ming 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
马维虎 MA Wei-hu 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
李杰 LI Jie 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
蒋伟宇 JIANG Wei-yu 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
宋小虎 SONG Xiao-hu 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
华群 HUA Qun 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
李国庆 LI Guo-qing 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
刘美学 LIU Mei-xue 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
于亮 YU Liang 宁波市第六医院脊柱外科, 浙江 宁波 315040 Department of Spinal Surgery, the 6th Hospital of Ningbo, Ningbo 315040, Zhejiang, China  
期刊信息:《中国骨伤》2014年27卷,第5期,第390-394页
DOI:10.3969/j.issn.1003-0034.2014.05.009


目的:研究下颈椎前路椎弓根螺钉钢板系统运用的可行性,为临床使用提供依据。

方法:对16具颈椎标本随机分割获得C3,4,C4,5,C5,6,C6,7各8个运动单元(functional spinal unit,FSU),共32个FSU.运用下颈椎前路椎弓根螺钉钢板系统模拟植入重建FSU稳定性。测量钢板螺钉与椎体之间的适应性,运用X线摄片及CT扫描及重建评估下颈椎前路椎弓根螺钉植入的准确性,对于穿破椎弓根的标本,解剖明确其累及周围组织的情况。

结果:32个FSU共计植入下颈椎前路椎弓根螺钉64枚,所有螺钉均顺利植入,无术中植入困难者。螺钉植入后与钢板螺钉孔之间的匹配程度好,未见难以锁紧的情况。钢板与椎体之间适应性良好。X线片提示所有64枚下颈椎前路椎弓根螺钉植入位置满意,螺钉长短合适。CT横断位像提示共有6枚螺钉在下颈椎椎弓根穿出,2枚内侧皮质1度穿破,4枚1度外侧缘皮质穿破累及横突孔内侧缘,未见螺钉≥2度穿破椎弓根。2枚下颈椎前路椎弓根内侧皮质1度穿破的患者,解剖发现仅有椎管内椎弓根内侧的静脉丛累及,未见硬膜囊受压,未见神经根受累。4枚1度外侧缘穿破的患者有1枚横突孔内椎静脉的累及,未见椎动脉穿破累及的情况,但其中1枚螺钉紧挨椎动脉而行。

结论:下颈椎前路椎弓根螺钉钢板系统适应下颈椎前路椎弓根螺钉固定重建,有临床运用价值。
[关键词]:颈椎  前路椎弓根螺钉钢板系统  植入物,实验性
 
The design and application of anterior cervical pedicle screw-plate system in lower cervical spine
Abstract:

Objective: To explore the applied feasibility of the anterior cervical pedicle screw-plate system in lower cervical spine,in order to provide basic data for clinical application.

Methods: Total thirty-two units (functional spinal unit,FSU)were got randomly from 16 cervical speciments,8 units in each group of C3,4,C4,5,C5,6 and C6,7. The anterior cervical pedicle screw-plate system was implanted to reconstruct the stability of FSU after discectomy and bone graft. The adaptability was measured between the screw-plate system and vertebral body. X-ray and CT were used to evaluate the accuracy of anterior cervical pedicle screws. The subject will be dissected to identify the situation of involvement if screw perforating the pedicle.

Results: Sixty-four anterior pedicle screws were inserted smoothly in the 32 units. The screw and the plate were harmonious locked in the system. The position and length of all screws were satisfactory through X-ray views. However,6 screws perforated the transpedicular (degree 1) according to CT axial views,2 internally cortex and 4 laterally cortex. None perforation was degree 2 or more. None cervical sac compression and nerve root injury was observed in two internal perforation cadavers. One vertebral vein involvement was found in the four lateral perforation screws. The vertebral artery was not pinched though one screw near to the artery.

Conclusion: The anterior cervical pedicle screw-plate system is adapted to reconstruct in lower cervical spine and it deserved to be used for clinical application.
KEYWORDS:Cervical vertebrae  Anterior cervical pedicle screw-plate system(ATPS)  Implants,experimental
 
引用本文,请按以下格式著录参考文献:
中文格式:赵刘军,徐荣明,马维虎,李杰,蒋伟宇,宋小虎,华群,李国庆,刘美学,于亮.下颈椎前路椎弓根螺钉固定系统的设计与运用[J].中国骨伤,2014,27(5):390~394
英文格式:ZHAO Liu-jun,XU Rong-ming,MA Wei-hu,LI Jie,JIANG Wei-yu,SONG Xiao-hu,HUA Qun,LI Guo-qing,LIU Mei-xue,YU Liang.The design and application of anterior cervical pedicle screw-plate system in lower cervical spine[J].zhongguo gu shang / China J Orthop Trauma ,2014,27(5):390~394
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com