Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
骶髂关节紊乱在X线片上的表现形式和临床意义
Hits: 2556   Download times: 1545   Received:July 10, 2012    
作者Author单位UnitE-Mail
师宁宁 SHI Ning-ning 甘肃省中医院针灸推拿科,甘肃 兰州 730050 Department of Acupuncture and Tuina,Gansu Province Hospital of Traditional Chinese Medicine,Lanzhou 730050,Gansu,China shingnig@sohu.com 
沈国权 SHEN Guo-quan 上海中医药大学附属岳阳中西医结合医院推拿科,上海 200437  
何水勇 HE Shui-yong 江西省中医院针灸推拿科,江西 南昌 330019  
郭汝宝 GUO Ru-bao 上海中医药大学附属岳阳中西医结合医院推拿科,上海 200437  
期刊信息:《中国骨伤》2013年26卷,第2期,第102-106页
DOI:10.3969/j.issn.1003-0034.2013.02.005
基金项目:国家自然科学基金(编号:83371158)


目的:研究骶髂关节紊乱在X线片上的表现形式和临床意义,为推拿手法治疗骶髂关节紊乱提供临床诊断依据.

方法:自2009年7月至2011年3月,选取104例骶髂关节紊乱的患者,其中男64例,女40例;年龄18~81岁,平均(45.39±1.30)岁;病程1~144个月,平均(12.64±2.19)个月.拍摄患者的骨盆平片104张,腰椎侧位片97张.在腰椎侧位片测量骶骨的水平角(腰骶角),骨盆平片上测量两侧髂嵴的垂直距离(髂嵴差),髋骨内侧缘与外侧缘之间的距离(髋骨宽),骶嵴连线与垂直轴线的夹角(骶嵴左右偏移度).

结果:两侧髂嵴差的均值为(10.34±0.73) mm,髋骨宽度差的均值为(6.73±1.01) mm;髂嵴差的均值较大(P < 0.01),髋骨不等宽出现的频率较高(P < 0.01).腰骶角异常的均值是(7.29±1.86)°,骶嵴左右偏移度的均值是(3.18±0.47)°;腰骶角异常的均值较大(P < 0.01),骶嵴左右偏移的频率较高(P < 0.01).

结论:骶髂关节紊乱可分为髂骨紊乱和骶骨紊乱,髂骨是旋转移位,可分为前后旋转和内外旋转移位,内外旋转频率高,前后旋转幅度大;骶骨是倾斜紊乱,可分为前后倾斜和左右倾斜移位,左右倾斜频率高,前后倾斜角度大.
[关键词]:骶髂关节  生物力学  放射摄影术
 
X-ray characteristics of sacroiliac joint disorders and its clinical significance
Abstract:

Objective:To study the X-ray characteristics of sacroiliac joint disorders and its clinical significance,so as to provide clinical diagnosis basis for Tuina treatment of sacroiliac joint disorder.

Methods:From July 2009 to March 2011,104 patients with sacroiliac joint disorder were reviewed,including 64 males and 40 females,ranging in age from 18 to 81 years,with an average of (45.39 ± 1.30) years. The duration of the disease ranged from 1 to 144 months,with an average of (12.64 ± 2.19) months. One hundred and four pelvic plain films and 97 lumbar spine lateral films of the patients with sacroiliac joint disorder were taken. On the lateral X-ray of lumbar,the sacral horizontal angles(lumbosacral angle) were measured; and on the X-ray of pelvis,the vertical distance of two side iliac crest (iliac crest difference),the distance from lateral border to medial margin of two hips (hip width),the clip angle between sacral spin connection and vertical axis were measured,and then the data were analyzed.

Results:The mean difference of iliac crest was (10.34±0.73) mm; the mean width difference of hip was (6.73±1.01) mm; and the mean difference of the iliac crest was larger than that of mean difference of hip(P < 0.01). The occurrence rate of inequal width of hip was higher(P < 0.01). The mean abnormal lumbosacral angle was (7.29 ± 1.86)°,and the mean angle of sacral crest tilting to left or right was (3.18 ± 0.47) °;the mean abnormal lumbosacral angle was larger than that of angle of sacral crest tilting to left or right(P < 0.01),and the occurrence rate of sacral crest tilting to left or right was higher(P < 0.01).

Conclusion:Sacroiliac joint disorders may be divided into iliac disorders and sacral disorders. The distance of iliac bone is rotating displacement,including anteroposterior rotation displacement,internal and external rotation displacement. The occurrence rate of internal and external rotation is higher than that of anteroposterior rotation;and the distance of the anteroposterior rotation is larger than that of internal and external rotation. The tilting of sacrum includes forward and backward tilting displacement,left and right tilting displacement;the occurrence rate of left and right tilting is higher,and the angle of the forward and backward tilting is larger.
KEYWORDS:Sacroiliac joint  Biomechanics  Radiography
 
引用本文,请按以下格式著录参考文献:
中文格式:师宁宁,沈国权,何水勇,郭汝宝.骶髂关节紊乱在X线片上的表现形式和临床意义[J].中国骨伤,2013,26(2):102~106
英文格式:SHI Ning-ning,SHEN Guo-quan,HE Shui-yong,GUO Ru-bao.X-ray characteristics of sacroiliac joint disorders and its clinical significance[J].zhongguo gu shang / China J Orthop Trauma ,2013,26(2):102~106
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com