低强度超声对幼龄白兔脊柱植骨融合的生物力学影响
Hits: 2038   Download times: 1396   Received:June 25, 2008    
作者Author单位UnitE-Mail
费骏 FEI Jun 浙江省中西医结合医院,浙江 杭州 310003 Zhejinag TCM&Westen Medicine Hospital,Hhangzhou 310003,Zhejiang,China jamfee67@medmail.com.cn 
莫斌 MO Bin 浙江中医药大学  
毕大卫 BI Da-wei 杭州市萧山区第一人民医院  
王以进 WANG Yi-jin 上海大学生物力学工程研究所  
林立 LIN Li 杭州东晶福田医疗器械有限公司  
期刊信息:《中国骨伤》2008年21卷,第11期,第846-849页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:浙江中医药管理局资助项目(编号:2004c141)


目的:评估低强度超声对脊柱植骨融合的生物力学影响。

方法:40只12月龄大白兔制成腰椎双节段同侧横突间后外侧脊柱植骨模型, 随机分试验组(B组)和对照组(A组).试验组用脉冲式超声刺激,6周后处死进行生物力学载荷、强度、刚度、扭转等测试比较。

结果:植骨融合6周时,试验组强度、刚度、扭矩和抗扭刚度、极限载荷均比对照组高6%~7%(P>0.05).

结论:低强度超声可以促进幼龄白兔脊柱植骨融合强度,加速骨折愈合。
[关键词]:低强度超声  骨移植  脊柱融合  生物力学
 
Influence of the fusion of bone graft in spine of rabbit treated with lower intensity ultrasound
Abstract:

Objective: To observe the influence of the fusion of bone graft in spine of rabbits which were treated with lower intensity ultrasound.

Methods: Forty 12-month-old rabbits were made to be the models of bone graft in post-lateral between two homonymy processus transverses in lumbar,and divided into treatment group(B)and control group (A)randomly. Twenty rabbits of treatment group were treated with lower intensity ultrasound,killed after six weeks,and took radiological examination,measured indexs of biomechanics.

Results: After 6 weeks of fusion of bone graft,treatment group were higher 6%-7%(P>0.05)in strength,rigidity,torque andantitwist,maxload than that of control group.

Conclusion: Lower intensity ultrasound can promote the speed and strength fusion of bone graft in young rabbits.
KEYWORDS:Lower intensity ultrasound  Bone transplantation  Spinal fusion  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:费骏,莫斌,毕大卫,王以进,林立.低强度超声对幼龄白兔脊柱植骨融合的生物力学影响[J].中国骨伤,2008,21(11):846~849
英文格式:FEI Jun,MO Bin,BI Da-wei,WANG Yi-jin,LIN Li.Influence of the fusion of bone graft in spine of rabbit treated with lower intensity ultrasound[J].zhongguo gu shang / China J Orthop Trauma ,2008,21(11):846~849