Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
骨骺生长滑动钢板的设计及动物实验研究
Hits: 2128   Download times: 1472   Received:March 26, 2008    
作者Author单位UnitE-Mail
练克俭 LIAN Ke-jian 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
洪加源 HONG Jia-yuan 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China hongjy175@yahoo.com.cn 
纪玉清 JI Yu-qing 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
丁真奇 DING Zhen-qi 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
林斌 LIN Bin 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
翟文亮 ZHAI Wen-liang 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
陈长青 CHEN Chang-qing 解放军175医院全军创伤骨科中心 厦门大学附属东南医院骨科,福建 漳州 363000 Department of Orthopaedics,the 175th Hospital of PLA,Zhangzhou 363000,Fujian,China  
期刊信息:《中国骨伤》2008年21卷,第10期,第752-756页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:南京军区十一五规划重点课题(编号:06Z30)


目的:设计一种骨骺部可滑动延长钢板,通过动物实验了解该钢板在动物体内能否在有效固定骨折的同时,又能减轻对骨骼纵向生长的抑制,减少肢体畸形的发生。

方法:根据儿童、青少年股骨髁部的解剖特点设计出适用于儿童、青少年股骨髁部骨折的内固定滑动钢板。实验动物选30只1.5月龄健康山羊,12只为正常对照组,余18只为钢板内固定组,其中右后肢采用普通钢板固定,左后肢采用滑动钢板固定。术后不同时相点对所有山羊双侧股骨进行X线摄片检查和使用组织化学、电镜观察评估骨骺细胞的生长情况。

结果:X线摄片检查钢板内固定组在术后1 d双侧股骨长度差异无统计学意义,在术后1、2、4、6个月双侧股骨长度差异有统计学意义,可滑动延长钢板侧股骨长度明显长于普通钢板侧,股骨长度术后1、2、4、6个月分别与术后1 d增长的数值进行比较分析,普通钢板侧和正常对照组右侧股骨长度差异有统计学意义,可滑动延长钢板侧和正常对照组左侧股骨长度差异无统计学意义(P>0.05);光镜观察示滑动组骨骺板总厚度及肥大细胞计数均明显大于普通钢板固定组(P<0.01);Safranine O组织化学观察示滑动组于术后3、6个月Safranine O组织化学染色明显深于普通组;电镜观察示滑动组于术后3、6个月软骨增殖区软骨细胞分裂及生长活跃。

结论:动物实验证实可滑动钢板在动物体内随骨骺的生长可自动延长,对骺板无加压抑制作用,能明显减少继发骺板损伤,不会产生骨骺生长抑制、骨骺早闭,符合发育期骨骺生长的生理特点。
[关键词]:骨骺  滑动钢板  骨折固定术,内  动物实验
 
Design and experimental study of an epiphyseal slide-traction plate
Abstract:

Objective: To develop an epiphyseal slide-traction plate in child,which can supply the fracture a sufficient internal fixation,and will not restrain the growth of epiphyses. Animal experiments were carried out with the plates to compare the slide-traction with traditional plate.

Methods: Develop a slide-traction plate for the configuration of the femur condylus of children. Thirty adolescent goats in the experiment were divided into control group(12 goats) and plate group(18 goats). In plate group,right femurs of goats were fixed with common plates and the left femurs with slide-traction plates. All the goats were given X-ray examination at different time after surgery. And the goats were sacrificed at 3 and 6 month,histological method and electron microscopy were performed to evaluate the development of epiphyseal plate.

Results: The both femurs of the goats in control group have no difference in evidence in length at all time we examined. And the both femurs of the goats fixed with plates have no difference in evidence in length at 1 day after surgery. However,the both femurs of the goats fixed with plates have difference in evidence in length at 1 month,2 month,3 month,6 month after surgery. The increased length of the femurs at 1 month,2 month,3 month,6 month after surgery was also compared with the length at 1 day after surgery,there was difference in evidence between the right femurs of the control group and the femurs were fixed with common plates, but no difference in evidence between the left femurs of the normal control group and the femurs were fixed with slide-traction plate(P>0.05). More thicker epiphyseal plate were found in the left femurs than the right femurs of the group fixed with plates at 3 and 6 month after surgery(P<0.01). In the plate group,safranine O staining showed epiphyseal plates at the left femurs had more fuscous staining than the right femurs at 3 and 6 month after surgery and electron microscopy also found that the cells of the epiphyseal plates of left femurs were more eugenic than the right femurs at 3 and 6 month after surgery.

Conclusion: The epiphyseal slide-traction plate can slide with the growth of epiphyses,which is suitable for fixation of the fracture in this part.
KEYWORDS:Epiphyses  Slide-traction plate  Fracture fixation,internal  Animal experimentation
 
引用本文,请按以下格式著录参考文献:
中文格式:练克俭,洪加源,纪玉清,丁真奇,林斌,翟文亮,陈长青.骨骺生长滑动钢板的设计及动物实验研究[J].中国骨伤,2008,21(10):752~756
英文格式:LIAN Ke-jian,HONG Jia-yuan,JI Yu-qing,DING Zhen-qi,LIN Bin,ZHAI Wen-liang,CHEN Chang-qing.Design and experimental study of an epiphyseal slide-traction plate[J].zhongguo gu shang / China J Orthop Trauma ,2008,21(10):752~756
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com