空心钉和骨圆针固定治疗股骨转子间骨折的力学随机对照试验
Hits: 2109   Download times: 1435   Received:January 04, 2007    
作者Author单位UnitE-Mail
孔令英 KONG Ling-ying 第六医院骨科,北京100007 Department of Orthopaedics,the Sixth Hospital of Beijing,Beijing 100007,China klying12@sina.com 
刘瑞波 LIU Rui-bo 第六医院骨科,北京100007 Department of Orthopaedics,the Sixth Hospital of Beijing,Beijing 100007,China  
王建辉 WANG Jian-hui 第六医院骨科,北京100007 Department of Orthopaedics,the Sixth Hospital of Beijing,Beijing 100007,China  
期刊信息:《中国骨伤》2007年20卷,第12期,第833-835页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:通过与4枚斯氏针固定比较,利用生物力学方法评价多枚空心钉固定股骨转子骨折的适应证和可靠性。

方法:使用Sawbone股骨模型,模拟EvansⅢA型骨折,分别用2种多枚空心钉方法(矩外空心钉和矩内空心钉法)及多枚骨圆针固定,在CSS-11101力学实验机上进行载荷试验,取300 N载荷下股骨头垂直位移和张口位移数值,比较3种方法的轴向刚度。通过扭转实验比较3种固定方法的抗扭转能力。

结果:3种固定方法在轴向刚度方面差异有统计学意义(P<0.05),而抗扭转能力方面差异无统计学意义(P>0.05)。

结论:矩外空心钉固定力学性能相似于4枚骨圆针,而矩内空心钉固定弱于4枚骨圆针。应用多枚空心钉固定应选择稳定型股骨转子间骨折。
[关键词]:股骨骨折  骨折固定术  生物力学  随机对照试验  
 
A randomized controlled trial on mechanics between cannulated cancellous screws and multi-steinmann pins for the treatment of intertrochanteric fractures
Abstract:

Objective:Using biomechanical test to evaluate the reliability and indication of multiple cannulated cancellous scews techniques for the treatment of intertrochanteric fractures.

Methods:Fifteen Sawbone models of femur with simulated intertrochanteric fractures(Evans ⅢA type) were stabilized with random assignment to 1 of 3 methods of fixation:①2 parallel 6.5 mm cannulated cancellous scews and a cancellous screw placed inferiorly through outside the calcar into femur head;②3 parallel 6.5 mm cannulated cancellous screws;③multi-steinmann pins.Axial and torsion loading were subjected to the three groups in CSS-11101 testing system.

Results:At axial loading 300 N,stiffness in three groups had significant difference(P<0.05).There were no statistical significant difference in torsion testing behavior between the 3 fixation methods.

Conclusion: Multiple cancellous screws with a screw outside the calcar provide stability and are able to resist displacement of the fracture similar to multi-steinmann pins.It is recommended for the treatment of stable intertrochanteric fractures in selected patients.
KEYWORDS:Femoral fractures  Fracture fixation  Biomechanics  Randomized controlled trials  
 
引用本文,请按以下格式著录参考文献:
中文格式:孔令英,刘瑞波,王建辉.空心钉和骨圆针固定治疗股骨转子间骨折的力学随机对照试验[J].中国骨伤,2007,20(12):833~835
英文格式:KONG Ling-ying,LIU Rui-bo,WANG Jian-hui.A randomized controlled trial on mechanics between cannulated cancellous screws and multi-steinmann pins for the treatment of intertrochanteric fractures[J].zhongguo gu shang / China J Orthop Trauma ,2007,20(12):833~835