冲击载荷作用下骨盆三维有限元分析及其生物力学意义
Hits: 2420   Download times: 1487   Received:April 01, 2007    
作者Author单位UnitE-Mail
苏佳灿 SU Jia-can 第二军医大学附属长海医院骨科,上海200433 Department of Orthopaedics,the Affiliated Changhai Hospital of the Second Military Medical University,Shanghai 200433,China sujiacan@sohu.com 
管华鹏 GUAN Hua-peng 第二军医大学附属长海医院骨科,上海200433 Department of Orthopaedics,the Affiliated Changhai Hospital of the Second Military Medical University,Shanghai 200433,China  
张春才 ZHANG Chun-cai 第二军医大学附属长海医院骨科,上海200433 Department of Orthopaedics,the Affiliated Changhai Hospital of the Second Military Medical University,Shanghai 200433,China  
陈学强 CHEN Xue-qiang 同济大学生命科学与技术学院  
王保华 WANG Bao-hua 同济大学生命科学与技术学院  
吴建国 WU Jian-guo 同济大学生命科学与技术学院  
丁祖泉 DING Zu-quan 同济大学生命科学与技术学院  
期刊信息:《中国骨伤》2007年20卷,第7期,第455-457页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:第二军医大学长海医院258资助项目(编号:258-5)


目的:探讨骨盆受到冲击载荷作用的力学行为特征,为临床分析及判断骨盆骨折类型、力学分布、冲击载荷影响提供力学基础。

方法:采用计算机仿真模拟方法,将所构建骨盆三维实体模型导入三维有限元分析软件AN-SYS7.0,计算单侧髂前上棘和单侧髂骨正后方部位冲击载荷作用下骨盆的力学行为表现,冲击载荷为0~8000N,峰值8000N,时间自0~40ms,分析主应力值、应力分布情况以及主应力方向上骨盆单元的位移。

结果:冲击载荷作用于单侧髂前上棘时,0~10ms主要的应力沿髂后上棘到髂前上棘分布,在冲击后期10ms以后,骶髂关节、髋臼和耻骨支都会产生较大的应力分布;作用于单侧髂骨正后方部位时,0~20ms主要的应力沿髂骨纵行传导,应力分布并没有在冲击峰值10ms时达到最大,而是从20ms之后,应力开始向骶髂关节、双侧耻骨支、坐骨支以及髋臼等部位传导并可见到明显的应力分布。

结论:分析冲击载荷作用下骨盆各部位应力分布以及骨盆各个单元在应力作用下的位移变化,有助于临床上进行骨盆损伤内固定力点的选择以及进一步明确骨盆内在应力值分布。
[关键词]:骨盆  冲击载荷  有限元分析  生物力学
 
Three-dimensional finite element analysis of pelvis loaded by transient stress and its biomechanical significance
Abstract:

Objective:To explore the mechanical behavior of pelvis loaded by transient stress and provide the mechanical basis for analyzing and judging pelvic fracture classification and mechanical distribution and transient stress affection in clinics.

Methods:By means of computer simulation,reading input from reconstructed pelvic three-dimensional model into three-dimensional finite element analysis software ANSYS 7.0,calculated the pelvic mechanical behavior and analyzed the main stress value,stress distribution and pelvic unit displacement in the direction of main stress when unilateral anterior superior iliac spine and unilateral positive backside of ilium was loaded by transient stress,the stress region was 0-8 000 N,peak value was 8 000 N,time range was from 0 ms to 40 ms.

Results:When unilateral anterior superior iliac spine loaded by transient stress,0-10 ms,stress distributed from posterior superior iliac spine to anterior superior iliac spine,and on the last 10 ms,there were greater stress distribution around cacroiliac joint,acetabulum and pubic branch.When unilateral positive backside of ilium loaded,between 0 ms and 20 ms,stress transmitted along vertical direction of ilium,and after 20 ms,there were greater stress distribution on cacroiliac joint,both pubic branch,ischium branch and acetabulum.

Conclusion:Analyzing the stress distribution of pelvis and units displacement when transient stress was loaded,can provide internal fixation point for treatment of pelvic fracture and further understanding the stress distribution of pelvis.
KEYWORDS:Pelvis  Impulsive load  Element analysis  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:苏佳灿,管华鹏,张春才,陈学强,王保华,吴建国,丁祖泉.冲击载荷作用下骨盆三维有限元分析及其生物力学意义[J].中国骨伤,2007,20(7):455~457
英文格式:SU Jia-can,GUAN Hua-peng,ZHANG Chun-cai,CHEN Xue-qiang,WANG Bao-hua,WU Jian-guo,DING Zu-quan.Three-dimensional finite element analysis of pelvis loaded by transient stress and its biomechanical significance[J].zhongguo gu shang / China J Orthop Trauma ,2007,20(7):455~457
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com