可调悬吊式内固定器的研制及临床应用 |
Hits: 1821
Download times: 1235
Received:March 16, 2005
|
作者 | Author | 单位 | Unit | E-Mail |
周英杰 |
ZHOU Ying-jie |
洛阳正骨研究所,河南洛阳471002 |
Luoyang Orthopaedic-Traumatological Institute of Henan Province,Henan Luoyang,471002,China |
|
赵庆安 |
ZHAO Qing-an |
厦门市集美医院 |
|
|
马虎升 |
MA Hu-sheng |
洛阳正骨研究所,河南洛阳471002 |
Luoyang Orthopaedic-Traumatological Institute of Henan Province,Henan Luoyang,471002,China |
|
史相钦 |
SHI Xiang-qin |
洛阳正骨研究所,河南洛阳471002 |
Luoyang Orthopaedic-Traumatological Institute of Henan Province,Henan Luoyang,471002,China |
|
郑怀亮 |
ZHENG Huai-liang |
洛阳正骨研究所,河南洛阳471002 |
Luoyang Orthopaedic-Traumatological Institute of Henan Province,Henan Luoyang,471002,China |
|
曹海云 |
CAO Hai-yun |
洛阳正骨研究所,河南洛阳471002 |
Luoyang Orthopaedic-Traumatological Institute of Henan Province,Henan Luoyang,471002,China |
|
郭艳幸 |
GUO Yan-xing |
厦门市集美医院 |
|
|
|
期刊信息:《中国骨伤》2005年18卷,第7期,第385-387页 |
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz |
基金项目:河南省科技攻关计划资助课题(编号:0224630034) |
|
目的:评价可调悬吊式内固定器(adjustable hang-fixer,AHF)治疗腰椎滑脱的临床疗效。
方法:35例腰椎滑脱患者,男16例,女19例;年龄28~56岁;应用AHF复位固定,后外侧融合或椎板间开窗(interlaminar fenestration)或全椎板切除减压后,椎间植入Cage进行椎体间融合,对所有病例进行定期随访和影像学检查,通过影像学指标和临床功能进行疗效评估。
结果:随访6~36个月,平均18个月,融合率为100%,临床疗效综合评估:优29例,良5例,可1例,优良率97.1%。内固定松动、移位、矫正度丢失1例。
结论:AHF系统固定牢固,操作简单、安全,疗效可靠。 |
[关键词]:腰椎 脊椎前移 内固定器 |
|
Advanced development and clinical application of adjustable hang-fixer |
|
Abstract:
Objective:To evaluate the clinical effect of adjustable hang-fixer(AHF) on lumbar spondylolisthesis (LS).
Methods:Thirty-five patients of LS were treated with:①reduction and fixation by AHF;②lateral-posterior fusion and posterior decompression through interlaminar fenestration or laminectomy;③intervertebral fusion through intervertebral Cage implant.All the patients were given regular follow-up and image examinations,of which the therapeutic effects were evaluated.
Results:All the patients were followed up from 6 to 36 months with an average 18 months,the rate of the fusion reached 100%.According to standard of clinical effect:excellent 29 cases,good 5 cases,fair 1 case.The rate of excellent and good was 97.1%.Loosening,displacement of the fixation and the correction degree was lost in 1 case.
Conclusion:Being safe and simple in operation,the AHF system can produce stable fixation and reliable therapeutic effect. |
KEYWORDS:Lumbar vertebra Spondylolisthesis Internal fixation device |
|
引用本文,请按以下格式著录参考文献: |
中文格式: | 周英杰,赵庆安,马虎升,史相钦,郑怀亮,曹海云,郭艳幸.可调悬吊式内固定器的研制及临床应用[J].中国骨伤,2005,18(7):385~387 |
英文格式: | ZHOU Ying-jie,ZHAO Qing-an,MA Hu-sheng,SHI Xiang-qin,ZHENG Huai-liang,CAO Hai-yun,GUO Yan-xing.Advanced development and clinical application of adjustable hang-fixer[J].zhongguo gu shang / China J Orthop Trauma ,2005,18(7):385~387 |
|
View Full Text View/Add Comment Download reader |