Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
前路钛钢板加钛网植骨内固定治疗多节段脊髓型颈椎病作用评价
Hits: 2189   Download times: 1463   Received:December 12, 2003    
作者Author单位UnitE-Mail
金毅 JIN Yi 河南省人民医院骨科,河南郑州450003 Henan Provincial Hospital  
郑稼 ZHENG Jia 河南省人民医院骨科,河南郑州450003 Henan Provincial Hospital  
赵炬才 ZHAO Ju-cai 河南省人民医院骨科,河南郑州450003 Henan Provincial Hospital  
期刊信息:《中国骨伤》2004年17卷,第8期,第477-478页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:探讨前路钛钢板加钛网植骨内固定治疗多节段脊髓型颈椎病的效果及意义。

方法:总结1998年至2002年期间收治的25例有2~3个节段突出的脊髓型颈椎病行前路椎体次全切术前路钛钢板加钛网植骨内固定术。

结果:经平均12个月的随访,25例患者植骨全部融合,无钛网移位脱落,无螺钉松动、钢板断裂,神经功能得到了不同程度恢复。

结论:应用前路钛钢板加钛网植骨内固定术治疗有2~3个节段突出的脊髓型颈椎病是安全有效的。
[关键词]:脊髓型颈椎病  骨折固定术,内  外科手术
 
Evaluation on clinical application of titanium plate and mesh in multi-segmental cervical spondylotic myelopathy
Abstract:

Objective:To evaluate the application of titanium plate and titanium mesh in multi-segmental cervical spondylotic myelopathy anterior fixation.

Methods:Twenty-five patients of multi-segmental cervical spondylotic myelopathy were treated with anterior cervical corectomy and fixation with titanium plate and titanium mesh from 1998 to 2002.

Results:All the twenty-five patients of bone planted were in fusion.Titanium mesh shedding,screw loose,plate breaking were not found after follow-up for an average of twelve months.The function of nerve had been improved.

Conclusion:It is effective and safe that titanium plate and titanium mesh are fixed anterior in multi-segment cervical spondylotic myelopathy.
KEYWORDS:Cervical spondylotic myelopathy  Fracture fixation,internal  Surgical procedure, operative
 
引用本文,请按以下格式著录参考文献:
中文格式:金毅,郑稼,赵炬才.前路钛钢板加钛网植骨内固定治疗多节段脊髓型颈椎病作用评价[J].中国骨伤,2004,17(8):477~478
英文格式:JIN Yi,ZHENG Jia,ZHAO Ju-cai.Evaluation on clinical application of titanium plate and mesh in multi-segmental cervical spondylotic myelopathy[J].zhongguo gu shang / China J Orthop Trauma ,2004,17(8):477~478