骨质疏松股骨颈经CCPC强化后螺钉固定的生物力学研究
Hits: 1752   Download times: 1309   Received:October 18, 2002    
作者Author单位UnitE-Mail
张旭辉 ZHANG Xuhui 解放军第三七一医院骨科,河南新乡453000 The 371th Hospital of PLA, Henan Xinxiang453000  
裴国献 PEI Guoxian 第一军医大学南方医院  
魏宽海 WEI Kuanhai 第一军医大学南方医院  
期刊信息:《中国骨伤》2003年16卷,第7期,第414-415页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:河南省医药卫生科研重点项目(2002090)


目的:评价不同直径螺钉固定时添加复合磷酸钙骨水泥(CCPC)对骨质疏松股骨颈生物力学变化的影响。

方法:采用24个股骨上段标本,随机分为三组:深螺纹强化组、中等螺纹强化组和浅螺纹强化组。

结果 三组均灌注CCPC,深螺纹组、中螺纹组和浅螺纹组的螺钉初始松动加载力分别为(328.9±34.9)N、(335.7±26.6)N、(284.8±25.9)N;最大轴向拔出力分别为(369.5±21.9)N、(364.0±17.5)N、(305.6±24.5)N,深螺纹组、中螺纹组均和浅螺纹组差异有显著性意义(P<0.05)。

结论:螺钉直径与骨质疏松股骨颈强化后的稳定性有关。
[关键词]:骨质疏松  骨折固定术  生物力学
 
Biomechanics study on augmentation of osteoporotic femoral neck with screw and composite calsium phosphate cement
Abstract:

Objective:To evaluate the Biomechanics of different diameter screw in the osteoporotic femoral neck with calcium phosphate cement

Methods:Twenty-four femurs of superior segment were randomly divided into three groups:deep spiral group,secondary spiral group,shallow spiral group.CCPC was inserted in three groups.

Results:The initial mobile force and the pull-out strength for deep spiral group and shallow spiral group were as follows:(328.9±34.9)N,(284.8±25.9)N;(369.5±21.9)N、(305.6±24.5)N.The content of biomechanics in shallow spiral group are lower than that of other groups significantly.

Conclusion:The date suggest that diameter of screw was related to the internal fixation with Calcium phosphate cement in osteoporotic femoral neck.
KEYWORDS:Osteoporosis  Fracture fixation  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:张旭辉,裴国献,魏宽海.骨质疏松股骨颈经CCPC强化后螺钉固定的生物力学研究[J].中国骨伤,2003,16(7):414~415
英文格式:ZHANG Xuhui,PEI Guoxian,WEI Kuanhai.Biomechanics study on augmentation of osteoporotic femoral neck with screw and composite calsium phosphate cement[J].zhongguo gu shang / China J Orthop Trauma ,2003,16(7):414~415