应用神经延长架延长兔坐骨神经的实验研究
Hits: 1999   Download times: 1267   Received:January 30, 2002    
作者Author单位UnitE-Mail
金帅星 JIN Shuaixing 延边大学医学院附属医院急诊科,吉林延吉133000 Affiliated hospital of Medical College of Yanbian University Jilin Yanji 133000  
朴虎林 PIAO Hulin 延边大学医学院附属医院急诊科,吉林延吉133000 Affiliated hospital of Medical College of Yanbian University Jilin Yanji 133000  
石伟 SHI Wei 中国人民解放军第208医院  
朴华益 吉林省延边医疗保险管理中心  
张志刚 中国人民解放军第208医院  
金成峰 延边大学医学院附属医院急诊科,吉林延吉133000 Affiliated hospital of Medical College of Yanbian University Jilin Yanji 133000  
期刊信息:《中国骨伤》2003年16卷,第2期,第87-90页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:利用神经延长器延长周围神经,修复周围神经缺损,为临床应用提供依据。

方法:利用自制的神经延长架,每天分数次延长1mm,修复神经缺损10mm,9周后行电生理及组织学观察。

结果:延长段神经外膜血供基本正常,神经缺损修复后其神经刺激阈值与神经原位缝合组差异无显著性,与神经移植组差异有显著性,组织学观察,延长组和原位缝合组有基本正常组织结构,神经移植组有明显空泡变性,髓鞘凝固变性。

结论:应用神经延长装置,采用合适的连接方法,可有效的延长周围神经,修复神经缺损。
[关键词]:周围神经  神经移植  神经外科手术
 
An experimental study of rabbits sciatic nerve distracting lengthening with nerve lengthening device for repair of peripheral nerve injury
Abstract:

Objective:Using a nerve lengthening apparatus to distract nerve for repair of peripheral nerve injury and to provide a basis for clinical application

Methods:30 health domestic rabbits were divided into 4 groups.Group A,the injuried nerve was distracted;Group B,nerve was transpanted in primary position;Group C,anastomosis had been performed in between the cut nerve endings in primary position;Group D,branch of sciatic nerve was cut down.After 9 weeks of operation,electron physiological examination,histology observation and nerve fibre count were performed.

Results:Perineurium blood supply of lengthened nerve segment was almost normal.After repair of the injured nerve,the stimulation threshold value,showed no difference between Group A and Group B (P>0.05),but there was a difference between Group A and Group D (P<0.05),and there was a significant difference between Group A and Group C (P<0.01).Under optic microscope and electron microscope,it was found that there was an almost normal structure in Group A and Group C and there was a significant vacuole degeneration and myelin sheath coagulation degeneration.

Conclusion:Using nerve lengthening apparatus and suitable method of approximation,effective sciatic nerve lengthening can be done.After anastomosis,the injured nerve can be repaired.This study provides a new method of repairing nerve injury.
KEYWORDS:Peripheral nerves  Nerve transfer  Neurosurgery
 
引用本文,请按以下格式著录参考文献:
中文格式:金帅星,朴虎林,石伟,朴华益,张志刚,金成峰.应用神经延长架延长兔坐骨神经的实验研究[J].中国骨伤,2003,16(2):87~90
英文格式:JIN Shuaixing,PIAO Hulin,SHI Wei.An experimental study of rabbits sciatic nerve distracting lengthening with nerve lengthening device for repair of peripheral nerve injury[J].zhongguo gu shang / China J Orthop Trauma ,2003,16(2):87~90
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com