Ransford环在枕颈融合术中的应用 |
Hits: 2340
Download times: 1226
Received:November 20, 2001
|
作者 | Author | 单位 | Unit | E-Mail |
张建湘 |
ZHANG Jian xiang |
安徽医科大学附属医院,安徽合肥230022 |
The Affiliated Hospital of Anhui Medical University Anhui Hefei,230022 |
|
江曙 |
JIANG Shu |
安徽医科大学附属医院,安徽合肥230022 |
The Affiliated Hospital of Anhui Medical University Anhui Hefei,230022 |
|
杨庆国 |
YANG Qing guo |
安徽医科大学附属医院,安徽合肥230022 |
The Affiliated Hospital of Anhui Medical University Anhui Hefei,230022 |
|
申才良 |
|
安徽医科大学附属医院,安徽合肥230022 |
The Affiliated Hospital of Anhui Medical University Anhui Hefei,230022 |
|
任启光 |
|
安徽医科大学附属医院,安徽合肥230022 |
The Affiliated Hospital of Anhui Medical University Anhui Hefei,230022 |
|
|
期刊信息:《中国骨伤》2002年15卷,第5期,第265-267页 |
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz |
|
目的:评价Ransford环在枕颈融合术中的固定作用。
方法:9例陈旧性寰枢椎骨折脱位,5例枕颈区畸形行后路枕颈减压,髂骨植骨,用自制Ransford环颅骨下和椎板下钢丝固定,术后X线片观察枕颈植骨融合。
结果:13例随访6个月~4年,神经功能明显恢复,12例枕颈区骨性融合。 |
[关键词]:骨折 颈椎 骨折固定术 |
|
Ransford loop fixation for the treatment of occipitocervical stability |
|
Abstract:
Objective:To evaluate the value of fixation during bone fusion for patients undergone posterior occipitocervical decompression and Ransford loop fixation
Methods:9 cases of old odontoid fracture associated with atlantoaxial dislocation,five cases of congenital malformation of occipitocervical junction underwent occipitocervical decompression, autograft bone and posterior occipitocervical stabilization with use of a Ransford loop was affixed by sublaminar wires.
Results:13 patients were followed up from 6 to 48 months.Bone fusion was seen in 12 patients and non union with the graft broken in one case.All patients had the nerve function significantly improved.
Conclusion:Ransford loop has the advantage over bone grafting of providing rigid stabiblization and contributing to eventual bone fusion. < |
KEYWORDS:Fractures Cervical vertebrae Fracture fixation |
|
引用本文,请按以下格式著录参考文献: |
中文格式: | 张建湘,江曙,杨庆国,申才良,任启光.Ransford环在枕颈融合术中的应用[J].中国骨伤,2002,15(5):265~267 |
英文格式: | ZHANG Jian xiang,JIANG Shu,YANG Qing guo.Ransford loop fixation for the treatment of occipitocervical stability[J].zhongguo gu shang / China J Orthop Trauma ,2002,15(5):265~267 |
|
View Full Text View/Add Comment Download reader |