Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
单侧多功能外固定支架治疗骨创伤并发症分析及对策
Hits: 1702   Download times: 1261   Received:October 29, 2000  Revised:January 15, 2001  
作者Author单位UnitE-Mail
魏力今 WEI Li-jin 合肥市第一人民医院,安徽合肥230061 The 1st People's Hospital of Hefei,Anhui Hefei,230061  
苏家庆 SU Jia-qing 合肥市第一人民医院,安徽合肥230061 The 1st People's Hospital of Hefei,Anhui Hefei,230061  
期刊信息:《中国骨伤》2001年14卷,第12期,第714-715页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:对应用单侧多功能外固定支架(以下简称支架)治疗骨创伤所引起的各种并发症进行分析并提出对策。

方法:回顾1993~2000年3月应用支架治疗四肢骨折125例所发生的各种并发症,并进行分类统计。

结果:本组共发生7种并发症,其中钉道渗液27例,钉道感染3例,固定钉松动16例,延迟愈合9例,关节功能障碍11例(12肢),骨折成角、再移位5例,Sudeck骨萎缩1例。

结论:支架治疗骨折发生并发症有诸多原因,常是多种因素合并导致,如病例选择不当,术中操作失误,术后复查不认真,术后功能锻炼欠科学。
[关键词]:骨折,开放性  外固定器  并发症
 
Analysis and managements of multifunctional unilateral axial dynamic external fixation apparatus for fracture complications
Abstract:

Objective:To analyse the various complications caused by fracture treated with multifunctional unilateral axial dynamic external fixation apparatus (MUADEFA) and provide corresponding managements

Methods: 125 cases of fractures of the limbs were treated with MUADEFA resulted in complications from 1993 to March 2000 were reviewed.

Results:In the 125 cases,there were 7 types of complications; they were 27 cases of effusion of nail path,3 of infection of nail path,16 of nail instability,9 of delayed union,12 of joint malfunction,5 of fracture displacement and 1 of Sudeck atrophy.

Conclusion: There were several factors related to the complications with the use of MUADEFA;they included improper selection of case,misplay in operation,inadequate detailed postoperative follow-up and improper institution of functional exercise.
KEYWORDS:Fractures  open External fixators Complications
 
引用本文,请按以下格式著录参考文献:
中文格式:魏力今,苏家庆.单侧多功能外固定支架治疗骨创伤并发症分析及对策[J].中国骨伤,2001,14(12):714~715
英文格式:WEI Li-jin,SU Jia-qing.Analysis and managements of multifunctional unilateral axial dynamic external fixation apparatus for fracture complications[J].zhongguo gu shang / China J Orthop Trauma ,2001,14(12):714~715
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com