Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
穿针滑动固定家兔胫骨实验性骨折愈合过程断端位移测试
Hits: 1983   Download times: 1303   Received:December 11, 2000    
作者Author单位UnitE-Mail
钟红刚 ZHONG Hong gang 中国中医研究院骨伤科研究所,北京100700 Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700  
赵宏普 ZHAO Hong pu 中国中医研究院骨伤科研究所,北京100700 Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700  
宋跃 SONG Yue 中国中医研究院骨伤科研究所,北京100700 Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700  
赵勇 中国中医研究院骨伤科研究所,北京100700 Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700  
孟和 中国中医研究院骨伤科研究所,北京100700 Instiute of Orthopaedic and Traumatology,China Academy of TCM Beijing,100700  
期刊信息:《中国骨伤》2001年14卷,第10期,第604-605页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:研究骨折愈合过程中断端微动。

方法:采用穿针滑动固定家兔胫骨实验性骨折治疗动物模型,手术截骨造成横断骨折,骨折线位于胫骨中部,采用自制滑动固定器4针固定,针径15mm;采用霍尔元件磁场传感器测量位移。

结果:术后1天断端最大位移278±122微米,2周时为190±91微米,3周时为70±35微米,4周时为54±25微米。

结论:所采用的骨折治疗模型具有对骨折断端生物力学环境的测控能力,骨折断端微动的大小能反映骨折愈合的早期进程。
[关键词]:骨折  骨折固定术  生物力学
 
Measurement of the displacement of the fracture site in the healing progress of the rabbit tibia fixed by pins with sliding fixator
Abstract:

Objective:To investigate the micro movement of the fracture site

Methods: Fracture of rabbit tibia was fixed by pins with sliding fixator.The transverse fracture line at middle portion of the tibia was produced by osteotomy;the fracture was then fixed with 4 pins on the sliding fixator and the diameter of pins was 1 5mm;displacement was measured by Hauer magnetic field sensor.

Results:The displacement of the fracture site was 278±122 microns at the first day after operation,190±91 microns at 2 weeks,70±35 microns at 3 weeks and 54±25 microns at 4 weeks.

Conclusion:The fracture model enabled us to survey the biomechanical environment of the fracture site and the displacement of fracture site can reflect the healing progress of fracture.
KEYWORDS:Fractures  Fracture  frxation  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:钟红刚,赵宏普,宋跃,赵勇,孟和.穿针滑动固定家兔胫骨实验性骨折愈合过程断端位移测试[J].中国骨伤,2001,14(10):604~605
英文格式:ZHONG Hong gang,ZHAO Hong pu,SONG Yue.Measurement of the displacement of the fracture site in the healing progress of the rabbit tibia fixed by pins with sliding fixator[J].zhongguo gu shang / China J Orthop Trauma ,2001,14(10):604~605
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com