Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
单侧外固定器治疗胫腓骨开放性骨折的并发症及防治
Hits: 1836   Download times: 1198   Received:May 22, 2000  Revised:September 30, 2000  
作者Author单位UnitE-Mail
王斌 WANG Bin 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
贺西京 HE Xi jing 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
姬刚 JI Gang 澄城县医院  
王栋 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
刘晓刚 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
李浩鹏 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
吕惠茹 西安医科大学第二临床医学院,陕西西安7100 2nd Affiliated Hospital of Xi’an Medical University,Shanxi Xi’an,710004  
期刊信息:《中国骨伤》2001年14卷,第10期,第588-589页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:探讨应用单侧外固定器治疗胫腓骨开放性骨折的并发症及防治措施。

方法与结果:67例病人经4个月~8年的随访,共有15例病人出现6类并发症,其中针道炎性反应5例,固定针松动4例,关节活动受限2例,骨折延迟愈合3例,畸形愈合1例,腓神经损伤1例。

结论:认为并发症原因与外固定技术、手术操作、术后护理及功能锻炼有关,并对防治这些并发症提出一些手术注意事项及防治措施。
[关键词]:外固定器  并发症  骨折,开放性
 
Unilateral multifunctional external fixator for the treatment of complications of open fractrures of the tibia and fibula
Abstract:

Objective:To investigate the method of treatment of the complications of open fractures of the tibia and fibula using unilateral multifunctional external fixator

Methods: and

Results:67 cases were treated with unilateral multifunctional external fixator and followed up from 4 months to 8 years.15 cases had complications;among them,5 cases had inflammation of needle path,4 loosening of the fixation wire,2 had limitation of joint motion,3 had delayed unnion,1 healed with deformity and 1 injury of peroneal nerve.

Conclusion:The occurrence of complication were related to the technique of external fixator,operation,nursing care after operation and functional training.
KEYWORDS:External fixators Complications Fractures  open
 
引用本文,请按以下格式著录参考文献:
中文格式:王斌,贺西京,姬刚,王栋,刘晓刚,李浩鹏,吕惠茹.单侧外固定器治疗胫腓骨开放性骨折的并发症及防治[J].中国骨伤,2001,14(10):588~589
英文格式:WANG Bin,HE Xi jing,JI Gang.Unilateral multifunctional external fixator for the treatment of complications of open fractrures of the tibia and fibula[J].zhongguo gu shang / China J Orthop Trauma ,2001,14(10):588~589
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com