Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
哈氏棒治疗不稳定胸腰椎骨折脱位
Hits: 2649   Download times: 1373   Received:September 21, 1998  Revised:March 17, 1999  
作者Author单位UnitE-Mail
蔡立忠 CAI Li zhong 泉州市中医院,福建泉州362000 Quanzhou Hospital of TCM Fujian Quanzhou,362000  
钟国荣 ZHONG Guo rong 南京军区福州总医院,福建福州  
黄碧玲 HUANG Bi ling 泉州市中医院,福建泉州362000 Quanzhou Hospital of TCM Fujian Quanzhou,362000  
吴培增 泉州市中医院,福建泉州362000 Quanzhou Hospital of TCM Fujian Quanzhou,362000  
张建新 泉州市中医院,福建泉州362000 Quanzhou Hospital of TCM Fujian Quanzhou,362000  
陈学明 南京军区福州总医院,福建福州  
徐皓 南京军区福州总医院,福建福州  
期刊信息:《中国骨伤》2000年13卷,第9期,第537-538页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz


目的:总结哈氏棒在治疗不稳定胸腰椎骨折脱位中的优缺点及注意事项。

方法:87例均采用哈氏棒治疗。其中62例予以椎板切除减压及/或切开硬脊膜探查脊髓,25例行棘突打孔钢丝固定双棒,65例做了自体植骨融合术。

结果:48例经1~11年随访,平均5年4个月,22例完全康复,有14例发生各种并发症。

结论:哈氏棒是一种符合生物力学的内固定器材,具有较强的纵向撑开力,能使骨折脱位得到很好复位,但亦具有一些缺点,如术中能做到置钩前预制好骨孔,并将哈氏棒预弯成与伤段脊柱相应的生理弧度,加用钢丝固定双棒,行后路植骨融合,术后使用支架保护,严格无菌操作等,可大大降低并发症的发生。
[关键词]:脊柱损伤  骨折固定术,内  哈氏棒
 
Treatment of unstable thoracolumbar vertebra fracture and dislocation by Harrington rod
Abstract:

Objective:To evaluate the merits and shortcomings of Harrington rod for the treatment of unstable thoracolumbar vertebra fracture and to discuss the points of attention of the method.

Methods:87 cases were treated with Harrington rod.Laminectomy and/or exploration of the spinal cord were performed in 62 cases.Bilateral rods were fixed with the wire through spinal processes in 25 cases.Auto graft of bone were performed in 65 cases.

Results: 48 cases were followed up from 1 to 5 years after operation.The average follow up was 5 years and 4 months.22 cases recovered completely,and some various complications occurred in 14 cases.

Conclusion:Harrington rod is an effective internal fixation device for the reduction of fracture and dislocation of vertebra with its longitudinal stress.This device corresponds to the biomechanics of the spinal column.But during the operation,complications should be avoided or diminished by performing strict aseptic technique,bending of the rod to a proper physiological curvature which corresponds to injured spine,doing posterior bone grafting and using corset support after operation.
KEYWORDS:Spinal injuries Fracture fixation  internal Harrington rod
 
引用本文,请按以下格式著录参考文献:
中文格式:蔡立忠,钟国荣,黄碧玲,吴培增,张建新,陈学明,徐皓.哈氏棒治疗不稳定胸腰椎骨折脱位[J].中国骨伤,2000,13(9):537~538
英文格式:CAI Li zhong,ZHONG Guo rong,HUANG Bi ling.Treatment of unstable thoracolumbar vertebra fracture and dislocation by Harrington rod[J].zhongguo gu shang / China J Orthop Trauma ,2000,13(9):537~538
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com