小夹板固定对前臂微循环影响的实验研究
Hits: 1919   Download times: 1029   Received:October 06, 1995  Revised:May 30, 1996  
作者Author单位UnitE-Mail
刘振利 Liu Zhenli 河北省张家口市第251医院,075000 The 251 Hospital, Zhangjiakou City, Hebei Province 075000  
顾云伍 Gu Yunwu 天津市天津骨科医院  
张会生 Zhang Huisheng 河北省张家口市第251医院,075000 The 251 Hospital, Zhangjiakou City, Hebei Province 075000  
期刊信息:《中国骨伤》1997年10卷,第3期,第20-21页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
通过在正常前臂进行小夹板固定对前臂微循环影响的实验研究,结果表明:夹板对局部微循环有一定影响,而对全身血液循环和血液稠度影响不大。0~600g布带约束力时,微循环无明显变化。当布带的约束力影响到微循环时,如果不经常及时地进行功能活动,局部组织缺血缺氧将通过人体血液循环自身调节系统的调节作用,以改善局部微循环,但其改善程度远不及功能活动对微循环改善的程度。故适时适当调整布带的约束力和进行肢体功能活动能较好地消除夹板压力对微循环的影响。
[关键词]:小夹板  约束力  微循环
 
Effcet of Small Slint Fixation on Microcirculation of Forearm-and Experimental Study
Abstract:The effcets of small splint fixation on the microcirculation of normal forearm were studied experimentally.The results showed that there was certain effect of small splint on local microcirculation,but no obvious influence on general blood circulation and blood viscosity. As the restraint force of bandages applied from 0 to 600 g, there were no evident changes in local microcirculation. After the local microcirculation was affected by restraint force.without usual dirigation of the arm on time, the local microcirculation as well as the local ischemia and hypoxia would be improved through the regulation of the autoregulation system of general blood circulation,but such improvement was far inferior to that through dirigation. Therefore, the appropriate adjustment of restraint force of bandages at due course and the dirigation of extremities can eliminate the influence of compression of splint on microcirculation more effectively.
KEYWORDS:Small splint fixation  Restranit force  Microcirculation
 
引用本文,请按以下格式著录参考文献:
中文格式:刘振利,顾云伍,张会生.小夹板固定对前臂微循环影响的实验研究[J].中国骨伤,1997,10(3):20~21
英文格式:Liu Zhenli,Gu Yunwu,Zhang Huisheng.Effcet of Small Slint Fixation on Microcirculation of Forearm-and Experimental Study[J].zhongguo gu shang / China J Orthop Trauma ,1997,10(3):20~21