Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
自制框架内固定治疗脊柱骨折并截瘫的评价
Hits: 2177   Download times: 1234   Received:July 16, 1995  Revised:May 10, 1996  
作者Author单位UnitE-Mail
唐三元 Tang Sanyuan 解放军168医院  
徐永年 Xu Yongnian 广州军区武汉总医院,430770 Wuhan General Hospital, Guangzhou Military Re-gion 430070  
陈庄洪 Chen Zhunghong 广州军区武汉总医院,430770 Wuhan General Hospital, Guangzhou Military Re-gion 430070  
罗芝荣 广州军区武汉总医院,430770 Wuhan General Hospital, Guangzhou Military Re-gion 430070  
期刊信息:《中国骨伤》1997年10卷,第2期,第6-7页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
本文通过对自制框架结构内固定治疗12例胸腰椎骨折脱位并脊髓损伤病人的结果分析,认为框架结构具有独特的生物力学特性,其抗旋转及创奇能力优于Harrington捧,“n”形捧及Luque捧,但纵向撑开力不及Harrington律及Dick固定器。由于其为多节段固定.术后较为牢固,比较适用于无或轻度(I°~II°)椎体压缩的胸腰椎骨折脱位及下腰椎不稳定。文内对框架结构内固定的优缺点进行了评价。
[关键词]:框架结构  内固定  脊柱脊髓损伤
 
Evaluation of Treatment on Spine Fracture Combined with Paraplegia with Self-made Frame for Interanal Fixation
Abstract:After analysis of the therapeutic effect of thoracic and lumbar fracture and dislocation combined with spinal cord injury in 12 cases with self-made internal fixation frame.it was considered that the structure of frame has an unique characteristics of biomechanism:the ability of its anti rotation and anti-lateral bending are better than Harrington's rod.“∩”formed rod.and Luque rod,but its longitudinal oppening force is less than rhat of Harrington's rod and Dick's fixator. It is much firmer due to its multiple segmental fixation .and more suitahle for thoracic and lumbar vertebral fracture and dislcxation without or with I°-Ⅱ° vertebral compression.and in,tability of lower lumbar vertebrae. The advantages and drawbacks of the frame structure were evaluated.
KEYWORDS:Structure of frame  Interanl fixation  Injury of spine and spinal cord
 
引用本文,请按以下格式著录参考文献:
中文格式:唐三元,徐永年,陈庄洪,罗芝荣.自制框架内固定治疗脊柱骨折并截瘫的评价[J].中国骨伤,1997,10(2):6~7
英文格式:Tang Sanyuan,Xu Yongnian,Chen Zhunghong.Evaluation of Treatment on Spine Fracture Combined with Paraplegia with Self-made Frame for Interanal Fixation[J].zhongguo gu shang / China J Orthop Trauma ,1997,10(2):6~7
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com