Sponsor
  • ·
  • Chinese Association of
    Integrative Medicine;
    China Academy of Chinese
    Medicine Sciences
Editing
  • ·
  • Editorial Board of
    China Journal of
    Orthopaedics and Traumatology
Publishing
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
Overseas Distributor
  • ·
  • China International Book
    Trading Corporation
    P.O.Box 399,Beijing,China
    Code No.M587
Mail-order
  • ·
  • Publishing House,
    China Journal of
    Orthopaedics and Traumatology
    No.16A, Nanxiaojie, Dongzhimennei,
    Beijing 100700,China
    Tel:0086-10-84020925
    Fax:0086-10-84036581
    Http://www.zggszz.com
    E-mail:zggszz@sina.com
腰后关节紊乱症的病机和手法治疗生物力学研究
Hits: 3014   Download times: 1281       
作者Author单位UnitE-Mail
蒋位庄 Jiang Wei-zhuang 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
周卫 Zhou Wei 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
李星 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
章永东 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
钟红刚 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
孙运悫 北京信息工程学院  
马庆智 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
马达 中国中医研究院骨伤科研究所 Institute of Orthopaedics &
Traumatology,China Academy of Traditional Chinese Medicine 100700
 
黄志勇 北京信息工程学院  
期刊信息:《中国骨伤》1994年7卷,第3期,第5-8页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:国家自然科学基金
用微型传感器埋入法,测定腰椎后关节在不同姿势下的位移和受力情况,结果表明:其位移程度和方向受关节突形态的影响,脊柱活动时关节内压力集中在小关节的上端和下端,当某段关节失稳时,较邻近的小关节内压力增大8倍左右。对模拟旋转手法测定表明:后关节内压力呈波浪状变化,其下关节突出现向上→前→下→后的全方位移动。作者从生物力学的角度对腰后关节紊乱症的病机和手法治疗原理进行了探讨。
[关键词]:腰后关节紊乱症  微型传感器  生物力学
 
Study on pathogenesis of derangement of lumbar posterior intervertebral facet joint and biomechanics of manipulative treatment
Abstract:A microsensor was embedded to detect the displacement and receiving forces from lumbar posterior intervertebral facet joints with various postures.The results indicates that the degree and direction of displacement is influenced by morphology of the articular process,during motion of the spine,the intra-pressure of facet joints is concentrated on the superior and inferior ends of the facet joint.During instability of certain segment of the joint,there will be an increasing of around 8 times of intra-pressure within the facet joints.Results of measurement of mimic rotatory manipulative reduction indicate that there are undulant changes within the intra -pressure of posterior facet joints.All-round direction movements of the inferior facet joint toward upward- forward- downward- backward have been found.Based on the viewpoint of bio- mechanics,the pathogenesis of derangement of lumbar posterior intervertebral facet joint and principle of manipulative treatment are explorated by authors.
KEYWORDS:Derangement of lumbar  posterior  inteyvertebral facet joint  Microsensor  Biomechanics  Principle manipulative treatment
 
引用本文,请按以下格式著录参考文献:
中文格式:蒋位庄,周卫,李星,章永东,钟红刚,孙运悫,马庆智,马达,黄志勇.腰后关节紊乱症的病机和手法治疗生物力学研究[J].中国骨伤,1994,7(3):5~8
英文格式:Jiang Wei-zhuang,Zhou Wei.Study on pathogenesis of derangement of lumbar posterior intervertebral facet joint and biomechanics of manipulative treatment[J].zhongguo gu shang / China J Orthop Trauma ,1994,7(3):5~8
View Full Text  View/Add Comment  Download reader
Close




版权所有:Editorial Office of China Journal of Orthopaedics and Traumatology京ICP备12048066号  版权声明
地址:No.16A, Nanxiaojie, Dongzhimennei, Beijing 100700, China
电话:0086-10-84036581 传真:0086-10-84036581 Email:zggszz@sina.com