四种组合方法规划髋臼前柱置钉通道的比较研究
摘要点击次数: 371   全文下载次数: 177   投稿时间:2024-03-18    
作者Author单位AddressE-Mail
易礼杨 YI Li-yang 南华大学机械工程学院, 湖南 衡阳 421001 School of Mechanical Engineering, University of South China, Hengyang 421001, Hunan, China  
李必文 LI Bi-wen 南华大学机械工程学院, 湖南 衡阳 421001 School of Mechanical Engineering, University of South China, Hengyang 421001, Hunan, China libiwen68@163.com 
唐鹏 TANG Peng 南华大学机械工程学院, 湖南 衡阳 421001 School of Mechanical Engineering, University of South China, Hengyang 421001, Hunan, China  
唐虎 TANG Hu 南华大学机械工程学院, 湖南 衡阳 421001 School of Mechanical Engineering, University of South China, Hengyang 421001, Hunan, China  
谭文甫 TAN Wen-fu 南华大学附属第二医院创伤骨科, 湖南 衡阳 421001 Department of Orthopaedics Trauma, the Second Affiliated Hospital of University of South China, Hengyang 421001, Hunan, China  
期刊信息:《中国骨伤》2024年,第37卷,第8期,第801-807页
DOI:10.12200/j.issn.1003-0034.20231036
基金项目:南华大学博士科研启动资金项目(编号:2015XQD39)
中文摘要:

目的:探讨基于大密度点云数据实现对髋臼前柱置钉通道的全局优化。

方法:2022年1月至2023年1月行完整CT扫描成年人正常骨盆CT数据40例,其中男22例,女18例;年龄20~54岁。选取其中3个样本的医学影像数据进行试验研究。规划髋臼前柱置钉通道,针对现行CAD规划方法是否具有先进性的问题,提出了点云获取渠道相同、方向线创建软件各异、三维设计与虚拟试验软件相同的4种组合方法: Mimics+Imageware+UG、Mimics+3DReshaper+UG、Mimics+ZEISS Quality Suite+UG与Mimics+Design X+UG,并依据二次修剪模型的中心点点集和实体点云分别创建方向线,应用于3个髋臼样本左侧前柱置钉通道的规划。以未出现髋臼窝和耻骨穿破现象的最大内接圆柱体作为髋臼前柱的置钉安全通道来评价各方法的先进性。

结果:在选取相关特征明显的中心点点集作为样本点时,方向线的拟合效果均优于未去噪的实体点云拟合效果;Mimics+Imageware+UG和Mimics+3DReshaper+UG的组合方法在利用中心点点集进行规划时能够高效、稳定地获得理想的规划结果,分别在髋臼样本1、2、3中得到的最大内接圆直径为10.35、9.62、9.24 mm;方向线依据实体点云时,Mimics+ZEISS Quality Suite+UG和Mimics+Design X+UG的组合方法均不适用;而Mimics+3DReshaper+UG的实体点云去噪规划法可以稳定地获得数值最大的置钉安全通道,分别在髋臼样本1、2、3中得到的最大内接圆直径为10.66、10.96、9.48 mm。

结论:在进行髋臼内固定术时推荐置钉通道规划人员采用鲁棒性好的Mimics+Imageware+UG或Mimics+3DReshaper+UG中心点点集规划法,如果时间充裕,建议采用Mimics+3DReshaper+UG的实体点云去噪规划法以获得数值最大的置钉安全通道。
【关键词】髋臼前柱置钉通道  全局优化  方向线创建方法  规划差异机制
 
A comparative study of four combined methods for planning access to the anterior acetabular column for nail placemen
ABSTRACT  

Objective To investigate global optimisation of anterior acetabular column pinning channels can be achieved based on large density point cloud data.

Methods Data were collected on the CT scans of the normal pelvis in 40 adults from January 2022 to January 2023,including 22 males and 18 females,aged 20 to 54 years old. Medical imaging data from three of the samples were selected for experimental study. In planning access for anterior acetabular column pinning,to address the issue of whether the current CAD planning methods were advanced or not,four combinations of the same point cloud acquisition channels,different directional line creation software,and the same 3D design and virtual experiment software were proposed:Mimics+Imageware+UG,Mimics+3DReshaper+UG,Mimics+ZEISS Quality Suite+UG and Mimics+Design X+UG,and directional lines created based on the centroid point set and solid point cloud of the secondary pruning model,respectively,and it applied to the planning of the left anterior column pinning channel of the three acetabular samples. The maximum internally connected cylinder without acetabular socket and pubic bone penetration was used as a safe passage for nailing of the anterior acetabular column to evaluate the advancement of each method.

Results The fitting effect of the directional line was better than that of the unnoised solid point cloud when the central point set with obvious relevant features was selected as the sample points;and the combination of Mimics+Imageware+UG and Mimics+3DReshaper+UG could efficiently and stably obtain the desirable planning results when planning with the central point set,respectively,in the three acetabular samples 1,2,3. The maximum internal joint circle diameters obtained in samples 1,2,and 3 were 10.35 mm,9.62 mm,and 9.24 mm;and when the directional lines were based on the solid point cloud the combined methods of Mimics+ZEISS Quality Suite+UG and Mimics+Design X+UG were not applicable;whereas the Mimics+3DReshaper+UG the solid point cloud denoising planning method could stably obtain the maximum value of the safe channel for nail placement,and the maximum internal joint circle diameters obtained in acetabular samples 1,2,and 3 are 10.66 mm,10.96 mm,and 9.48 mm,respectively.

Conclusion It is recommended that the nail placement channel planners use robust Mimics+Imageware+UG or Mimics+3DReshaper+UG centre point set planning method,and if there is enough time,it is recommended to use the solid point cloud denoising planning method of Mimics+3DReshaper+UG in order to obtain the maximum value of safe channels for nail placement. Global optimisation; Direction line creation method; Planning variance mechanism;
KEY WORDS  Acetabular anterior column pinning access  Global optimisation  Direction line creation method  Planning variance mechanism  
 
引用本文,请按以下格式著录参考文献:
中文格式:易礼杨,李必文,唐鹏,唐虎,谭文甫.四种组合方法规划髋臼前柱置钉通道的比较研究[J].中国骨伤,2024,37(8):801~807
英文格式:YI Li-yang,LI Bi-wen,TANG Peng,TANG Hu,TAN Wen-fu.A comparative study of four combined methods for planning access to the anterior acetabular column for nail placemen[J].zhongguo gu shang / China J Orthop Trauma ,2024,37(8):801~807
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号