关节镜下免打结锚钉联合Endobutton钛板治疗后交叉韧带胫骨止点撕脱骨折
摘要点击次数: 1843   全文下载次数: 353   投稿时间:2021-04-19    
作者Author单位AddressE-Mail
赵智 ZHAO Zhi 重庆市中医骨科医院, 重庆 400010 Chongqing Orthopaedics Hospital of Traditional Chinese Medicine, Chongqing 400010, China  
邓煜 DENG Yu 重庆市中医骨科医院, 重庆 400010 Chongqing Orthopaedics Hospital of Traditional Chinese Medicine, Chongqing 400010, China 23218982@qq.com 
陈宇 CHEN Yu 重庆市中医骨科医院, 重庆 400010 Chongqing Orthopaedics Hospital of Traditional Chinese Medicine, Chongqing 400010, China  
白新文 BAI Xin-wen 重庆市中医骨科医院, 重庆 400010 Chongqing Orthopaedics Hospital of Traditional Chinese Medicine, Chongqing 400010, China  
期刊信息:《中国骨伤》2021年,第34卷,第12期,第1136-1140页
DOI:10.12200/j.issn.1003-0034.2021.12.009
基金项目:
中文摘要:

目的:探讨关节镜下采用免打结锚钉与Endobutton钛板联合固定后交叉韧带胫骨止点撕脱骨折的临床疗效。

方法:自2019年10月至2020年10月,采用关节镜下免打结锚钉联合Endobutton钛板治疗12例后交叉韧带胫骨止点撕脱骨折患者,其中男9例,女3例;年龄23~58岁;受伤至手术时间2~9 d。其中MeyersⅡ型2例,MeyersⅢ型10例;合并半月板损伤2例,内侧副韧带部分损伤1例。术后评估骨折愈合情况和膝关节活动度,并采用Lysholm功能评分进行临床疗效评价。

结果:所有患者获得12个月随访。所有患者在6个月内骨性愈合,且无切口感染、下肢深静脉血栓形成、内固定脱落等并发症发生。膝关节屈曲活动度从术前50°~90°恢复至术后6个月的115°~130°,无患者出现伸直障碍。Lysholm功能评分由术前29~54分恢复至术后12个月的86~100分。

结论:关节镜下采用免打结锚钉联合Endobutton钛板复位固定后交叉韧带胫骨止点撕脱骨折并发症少、骨折愈合率高、膝关节伸屈角度及功能恢复良好。
【关键词】后交叉韧带  胫骨止点撕脱骨折  关节镜  免打结锚钉
 
Arthroscopic treatment of tibial avulsion fracture of posterior cruciate ligament with a knot-free anchor and Endobuton titanium plate
ABSTRACT  

Objective: To investigate the clinical effect of arthroscopic fixation of tibial avulsion fracture of posterior cruciate ligament with a knot-free anchor and Endobuton titanium plate.

Methods: From October 2019 to October 2020,12 patients with tibial avulsion fracture of posterior cruciate ligament were treated with the arthroscopic knot-free anchor and Endobuton titanium plate,including 9 males and 3 females. The age ranged from 23 to 58 years old. The time from injury to operation ranged from 2 to 9 days. There were 2 cases of Meyers typeⅡand 10 cases of Meyers type Ⅲ. There were 2 cases of meniscus injury and 1 case of partial injury of medial collateral ligament. The fracture healing and knee range of motion were evaluated after operation,and the clinical efficacy was evaluated by Lysholm function score.

Results: All patients were followed up for 12 months. All patients healed within 6 months,and there were no complications such as incision infection,lower extremity deep venous thrombosis and internal fixation falling off. The knee flexion range of motion recovered from 50°-90° before operation to 115°-130° 6 months after operation,and no patient had straightening disorder. Lysholm functional score recovered from preoperative 29-54 scores to 86-100 scores 12 months after operation.

Conclusion: Arthroscopic reduction and fixation of tibial avulsion fracture of posterior cruciate ligament with the knot-free anchor and Endobuton titanium plate has less complications,high fracture healing rate,good extension and flexion angle and early function recovery of knee joint.
KEY WORDS  Posterior cruciate ligament  Tibial avulsion fracture  Arthroscopes  Knotless anchor
 
引用本文,请按以下格式著录参考文献:
中文格式:赵智,邓煜,陈宇,白新文.关节镜下免打结锚钉联合Endobutton钛板治疗后交叉韧带胫骨止点撕脱骨折[J].中国骨伤,2021,34(12):1136~1140
英文格式:ZHAO Zhi,DENG Yu,CHEN Yu,BAI Xin-wen.Arthroscopic treatment of tibial avulsion fracture of posterior cruciate ligament with a knot-free anchor and Endobuton titanium plate[J].zhongguo gu shang / China J Orthop Trauma ,2021,34(12):1136~1140
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号