自制微调装置在股骨交锁髓内钉远端锁钉过程中的应用
摘要点击次数: 1765   全文下载次数: 1070   投稿时间:2018-06-20    
作者Author单位AddressE-Mail
李运美 LI Yun-mei 沧州中西医结合医院骨六科, 河北 沧州 061001 Department of Orthopaedics, Cangzhou Hospital of Integrated TCM-WM, Cangzhou 061001, Hebei, China 172923438@qq.com 
邢宝瑞 XING Bao-rui 沧州中西医结合医院骨六科, 河北 沧州 061001 Department of Orthopaedics, Cangzhou Hospital of Integrated TCM-WM, Cangzhou 061001, Hebei, China  
郭东辉 GUO Dong-hui 沧州中西医结合医院骨六科, 河北 沧州 061001 Department of Orthopaedics, Cangzhou Hospital of Integrated TCM-WM, Cangzhou 061001, Hebei, China  
韩广普 HAN Guang-pu 沧州中西医结合医院骨六科, 河北 沧州 061001 Department of Orthopaedics, Cangzhou Hospital of Integrated TCM-WM, Cangzhou 061001, Hebei, China  
期刊信息:《中国骨伤》2019年,第32卷,第2期,第161-165页
DOI:10.3969/j.issn.1003-0034.2019.02.013
基金项目:
中文摘要:

目的:评价自制微调装置在股骨交锁髓内钉远端锁钉植入过程中的疗效。

方法:2014年10月至2017年10月采用顺行交锁髓内钉治疗股骨干骨折患者66例,男45例,女21例;年龄(37.21±11.18)岁。36例远端锁钉过程中采用髓内钉厂家自带的瞄准装置外加微调装置(研究组),30例远端锁钉过程中采用髓内钉厂家自带的瞄准装置(对照组),对比两组远端锁钉过程的手术时间及C形臂X线透视的次数、术后并发症、骨折愈合情况。

结果:62例患者获得随访,时间8~15个月,平均12.4个月。两组中术后并发症、骨折愈合情况比较差异无统计学意义(P>0.05),研究组远端锁钉耗时、透视次数明显少于对照组,差异有统计学意义(P<0.05)。

结论:自制微调装置在交锁髓内钉治疗股骨干骨折过程中,可以缩短手术时间,减少X线透视次数。
【关键词】股骨  骨折固定术,髓内  外科器械
 
Application of self-made fine-tuning device in distal locking process of femoral interlocking intramedullary nail
ABSTRACT  

Objective: To evaluate the curative efficacy of self-made fine-tuning setting in the process of femoral distal implantation of intramedullary nail.

Methods: From October 2015 to October 2017, 66 cases of femoral shaft fracture were treated with anterograde interlocking intramedullary nail including 45 males and 21 females with a mean age of (37.21±11.18) years old. Among them, 36 cases were treated with the manufacture's aiming device and self-made fine-tuning setting (research group), other 30 cases were treated with the manufacture's aiming device (control group). The mean operation time, the times of C-arm scan in surgery, the post-operation complications and the fracture union were observed and compared in two groups.

Results: Sixty-two cases acquired 8 to 15 months with a mean time of 12.4 months follow-up visit. The post-operation complications and the fracture union between the two groups had no significant difference (P>0.05), the mean operation time and the times of C-arm scan in surgery had statistically significant difference (P<0.05).

Conclution: Self-made fine-tuning setting in the process of femoral interblocking intramedullary nail could shorten operation time and reduce the the times of C-arm scan.
KEY WORDS  Femur  Fracture fixation,intramedullary  Surgical instruments
 
引用本文,请按以下格式著录参考文献:
中文格式:李运美,邢宝瑞,郭东辉,韩广普.自制微调装置在股骨交锁髓内钉远端锁钉过程中的应用[J].中国骨伤,2019,32(2):161~165
英文格式:LI Yun-mei,XING Bao-rui,GUO Dong-hui,HAN Guang-pu.Application of self-made fine-tuning device in distal locking process of femoral interlocking intramedullary nail[J].zhongguo gu shang / China J Orthop Trauma ,2019,32(2):161~165
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号