3D打印导向模板辅助下耻骨上支外侧髓内拉力螺钉置钉的临床应用
摘要点击次数: 1964   全文下载次数: 1214   投稿时间:2017-07-20    
作者Author单位AddressE-Mail
郑轶 ZHENG Yi 宁波市第二医院骨科, 浙江 宁波 315010 Department of Orthopaedics, Ningbo No. 2 Hospital, Ningbo 315010, Zhejiang, China 15967868807@163.com 
袁欣华 YUAN Xin-hua 宁波市第二医院骨科, 浙江 宁波 315010 Department of Orthopaedics, Ningbo No. 2 Hospital, Ningbo 315010, Zhejiang, China  
王伟斌 WANG Wei-bin 宁波市第二医院骨科, 浙江 宁波 315010 Department of Orthopaedics, Ningbo No. 2 Hospital, Ningbo 315010, Zhejiang, China  
扶青松 FU Qing-song 宁波市第二医院骨科, 浙江 宁波 315010 Department of Orthopaedics, Ningbo No. 2 Hospital, Ningbo 315010, Zhejiang, China  
庞清江 PANG Qing-jiang 宁波市第二医院骨科, 浙江 宁波 315010 Department of Orthopaedics, Ningbo No. 2 Hospital, Ningbo 315010, Zhejiang, China  
期刊信息:《中国骨伤》2017年,第30卷,第10期,第911-914页
DOI:10.3969/j.issn.1003-0034.2017.10.007
基金项目:宁波市科技富民惠民技术研发资助项目(编号:2015C50034);浙江省医药卫生一般研究计划(A类)(编号:2016KYA165);宁波市自然科学基金项目(编号:2016A610142)。
中文摘要:

目的:评价3D打印导向模板辅助下耻骨上支外侧髓内拉力螺钉的临床疗效和优势。

方法:2015年7月至2016年12月,符合纳入标准的耻骨上下支骨折患者20例,选择拉力螺钉固定手术方法,分为试验组和对照组,试验组导向模板辅助置钉,对照组常规手术置钉,试验组中男7例,女3例,年龄(46.20±3.03)岁,其中左侧耻骨上下支骨折6例,右侧耻骨上下支骨折4例;对照组中男6例,女4例,年龄(48.50±2.25)岁,左侧耻骨上下支骨折5例,右侧耻骨上下支骨折5例。对两组的手术时间、透视次数及出血量等数据进行统计分析。

结果:两组性别、年龄、骨折分型差异无统计学意义。试验组手术时间为(31.0±5.3) min,术中透视次数为(3.5±2.1)次,出血量为(75.6±10.5) ml;对照组手术时间为(55.0±6.8) min,术中透视次数为(27.6±3.2)次,出血量为(85.5±12.5) ml.两组患者的手术时间及术中透视次数比较差异有统计学意义(P<0.05),两组出血量比较差异无统计学意义。

结论:基于3D打印技术的个性化导向模板可实现逆向耻骨上支外侧髓内拉力螺钉置钉的精确置入,并且可以显着节省手术时间及减少患者及医护人员的射线暴露次数。
【关键词】外科手术,微创性  耻骨骨折  3D打印  导向模板
 
Clinical application of personalized 3D printing-guided template of intramedullary lag screw insertion on lateral superior ramous of pubic
ABSTRACT  

Objective:To evaluate the efficacy and advantages of personalized 3D printing-guided template of lateral superior ramous of pubic intramedullary lag screw.

Methods:From July 2015 to December 2016,20 patients with the superior and inferior ramous of pubis fracture were treated with lag screws placement. All the patients were divided into test group(with guided template) and control group(with general operation). There were 7 males and 3 females with an average age of (46.20±3.03) years old in test group and 6 males and 4 males with (48.50±2.25) years old in control group. There were 6 cases and 5 cases of superior and inferior branches fractures of pubic on the left side and 4 cases and 5 cases on the right side in two groups respectively. The operation time,perspective times and bleeding loss were compared between two groups.

Results:The test group and the control group had no statistically significant relative to gender,age,fracture classification. The average time of surgery,average intraoperative fluoroscopy times,mean blood loss in test group were (31.0±5.3) min,(3.5±2.1) times,(75.6±10.5) ml respectively,and in control group were(55.0±6.8) min,(27.6±3.2) times,(85.5±12.5) ml respectively. There were significant Statistical differences between two groups(P<0.05) in average operation time and average fluoroscopy times,however,mean blood loss had no significant differences between two groups(P>0.05).

Conclusion:The personalized guide template based on 3D printing technology could realize precise placement of the lateral intramedullary lag screw fixation in the superior branch of pubic,also could save the operation time and reduce the times of radiation exposure of patients and surgeons.
KEY WORDS  Surgical procedures,minimally invasive  Pubic fracture  Three-dimension print  Guided template
 
引用本文,请按以下格式著录参考文献:
中文格式:郑轶,袁欣华,王伟斌,扶青松,庞清江.3D打印导向模板辅助下耻骨上支外侧髓内拉力螺钉置钉的临床应用[J].中国骨伤,2017,30(10):911~914
英文格式:ZHENG Yi,YUAN Xin-hua,WANG Wei-bin,FU Qing-song,PANG Qing-jiang.Clinical application of personalized 3D printing-guided template of intramedullary lag screw insertion on lateral superior ramous of pubic[J].zhongguo gu shang / China J Orthop Trauma ,2017,30(10):911~914
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号