联合使用胫骨延长柄和金属垫片假体治疗膝关节置换胫骨缺损
摘要点击次数: 1828   全文下载次数: 1063   投稿时间:2015-12-02    
作者Author单位AddressE-Mail
韵向东 YUN Xiang-dong 兰州大学第二医院骨科, 甘肃 兰州 730030 Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China  
安丽萍 AN Li-ping 甘肃省骨关节疾病研究重点实验室, 甘肃 兰州 730030  
姜金 JIANG Jin 兰州大学第二医院骨科, 甘肃 兰州 730030 Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China  
姚长江 YAO Chang-jiang 兰州大学第二医院骨科, 甘肃 兰州 730030 Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China  
董海涛 DONG Hai-tao 兰州大学第二医院骨科, 甘肃 兰州 730030 Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China  
靳佳欣 JIN Jia-xin 兰州大学第二医院骨科, 甘肃 兰州 730030 Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China  
夏亚一 XIA Ya-yi 兰州大学第二医院骨科, 甘肃 兰州 730030
甘肃省骨关节疾病研究重点实验室, 甘肃 兰州 730030
Department of Orthopaedics, the Second Hospital Affiliated to Lanzhou University, Lanzhou 730030, Gansu, China xiayy@lzu.edu.cn 
期刊信息:《中国骨伤》2016年,第29卷,第5期,第472-475页
DOI:10.3969/j.issn.1003-0034.2016.05.017
基金项目:甘肃省自然科学基金(编号:1208RJZA273)
中文摘要:目的:探讨联合使用胫骨延长柄和金属垫片假体治疗胫骨缺损在膝关节置换中的应用。方法:回顾性分析2011年1月至2013年5月使用胫骨延长柄膝关节假体行人工全膝关节置换的10例(11膝)临床效果。全部为女性,平均年龄67岁(60~77岁).所有患者行膝关节CT检查,明确其内侧缺损程度,缺损程度均为T2A.均诊断为膝关节骨关节炎。手术前后使用KSS评分进行疗效评价。结果:10例患者平均手术时间100 min,术中使用止血带,术后均不放置引流,不输血。分别从行走能力、上下楼能力、疼痛、稳定性及活动度方面进行评分。与术前相比,术后12个月评分优于术前。未见感染病例。结论:联合使用胫骨延长柄和金属垫片假体作为治疗严重膝关节疾病的方法,术后功能恢复满意,能显着提高胫骨假体的稳定性。
【关键词】胫骨  关节成形术,置换,膝  关节炎,膝
 
Reconstruction of complex proximal tibial defects using the long-stem tibial component combined with metallic wedge
ABSTRACT  Objective: To investigate results of total knee arthroplasty using the long-stem tibial component combined with metallic wedge of knee prosthesis for the treatment of proximal defects. Methods: From January 2011 to May 2013,10 patients(11 knees) were treated with total knee arthroplasties using the long-stem tibial component with metallic tibial wedge of knee prosthesis. All the patients were female and the average age was 67 years old (ranged,60 to 77 years old). All the patients were osteoarthritis. All the patients were classified as T2A style. The patients were evaluated according to knee score system (KSS). Results: All the patients were followed up for 12 months on average(ranged 3 to 29 months). The clinical outcome was assessed using KSS score,including knee pain score,knee stability score,knee range of motion score and knee walking score,knee stairs score. There were significantly differences at 6 weeks,3 months,6 months and 12 months between pre-and postoperative KSS score. Conclusion: The mechanical stability of tibial fixation in primary TKA is significantly increased by using the long-stem tibial component with metallic wedge of knee prosthesis,even in the presence of poor proximal bone.
KEY WORDS  Tibia  Arthroplasty,replacement,knee  Osteoarthritis,knee
 
引用本文,请按以下格式著录参考文献:
中文格式:韵向东,安丽萍,姜金,姚长江,董海涛,靳佳欣,夏亚一.联合使用胫骨延长柄和金属垫片假体治疗膝关节置换胫骨缺损[J].中国骨伤,2016,29(5):472~475
英文格式:YUN Xiang-dong,AN Li-ping,JIANG Jin,YAO Chang-jiang,DONG Hai-tao,JIN Jia-xin,XIA Ya-yi.Reconstruction of complex proximal tibial defects using the long-stem tibial component combined with metallic wedge[J].zhongguo gu shang / China J Orthop Trauma ,2016,29(5):472~475
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号