Akagi线作为全膝关节置换胫骨近端假体旋转对线的可靠性研究 |
摘要点击次数: 2145
全文下载次数: 1236
投稿时间:2015-05-19
|
作者 | Author | 单位 | Address | E-Mail |
余华晨 |
YU Hua-chen |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
huachenyu@126.com |
温宏 |
WEN Hong |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
|
张宇 |
ZHANG Yu |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
|
胡月正 |
HU Yue-zheng |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
|
吴剑彬 |
WU Jian-bin |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
|
孔建中 |
KONG Jian-zhong |
温州医科大学附属第二医院骨科, 浙江 温州 325027 |
Department of Orthopaedics, the Second Affiliated Hospital of Wenzhou Medical University, Wenzhou 325027, Zhejiang, China |
|
|
期刊信息:《中国骨伤》2015年,第28卷,第10期,第884-887页 |
DOI:10.3969/j.issn.1003-0034.2015.10.002 |
基金项目:浙江省卫生厅科研基金资助项目(编号:2013KYB175);温州市科技计划项目(编号:Y20120174) |
|
中文摘要:
目的:在磁共振上测量全膝关节置换胫骨近端假体旋转对线的骨性标志,研究Akagi线作为TKA胫骨近端假体旋转对线的可靠性。
方法:2010年1月至2013年12月,80名健康成年人行膝关节磁共振扫描,男35例,女45例,平均年龄(35.4±6.1)岁。在股骨横断面图像上定位股骨外科髁上轴(STEA)并投射到胫骨侧形成STEA',在胫骨侧横断面图像上定位后交叉韧带止点中点与髌韧带内侧缘连线(Akagi线)及其垂线(AK),后交叉韧带止点中点与髌韧带中内1/3连线及其垂线(AP),比较AK、AP相对于STEA'的角度。
结果:AK与STEA‘的夹角为(0.59±2.07)°,与STEA'的平行线相比较,差异无统计学意义(t=-2.54,P=0.13);AP与STEA'夹角为(3.21±2.04)°,与STEA'的平行线相比较,差异有统计学意义(t=14.05,P<0.05).AK与AP比较,两线间走行方向差异较大(t=-11.68,P<0.05).
结论:Akagi线作为全膝关节置换胫骨近端假体旋转对线的可靠性高。 |
【关键词】关节成形术,置换,膝 胫骨 旋转 磁共振成像 |
|
Research on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty |
|
ABSTRACT
Objective:To study on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty(TKA),the rotational alignment reference bony landmarks of the proximal tibial component on magnetic resonance image(MRI) were measured.
Methods:From January 2010 to December 2013,80 normal knees of Chinese volunteers including 35 males and 45 females with an average age of (35.4±6.1) years were reviewed. The images of the knees were obtained by MRI. The surgical epicondylar axis (STEA) was identified in the femoral transverse sections and then was projected to the side of tibia,forming the SETA'. A line connecting the medial border of the patellar tendon and the middle of the posterior cruciate ligament insertion(Akagi line) and its vertical line(AK),as well as a line connecting the medial 1/3 of the patellar tendon and the middle of the posterior cruciate ligament insertion and its vertical line(AP),were identified in the tibial transverse sections. The angles were measured between the AK,AP and STEA'.
Results:The angle between AK and STEA' was (0.59 ±2.07)°,and there was no significant difference between the two lines(t=-2.54,P=0.13). The mean angle between AP and STEA' was (3.21±2.04)°,and there was a significant difference between the two lines(t=14.05,P<0.05). There was a significant difference between the AK and AP(t=-11.68,P<0.05).
Conclusion:The reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in TKA is good. |
KEY WORDS Arthroplasty, replacement, knee Tibia Rotation Magnetic resonance imaging |
|
引用本文,请按以下格式著录参考文献: |
中文格式: | 余华晨,温宏,张宇,胡月正,吴剑彬,孔建中.Akagi线作为全膝关节置换胫骨近端假体旋转对线的可靠性研究[J].中国骨伤,2015,28(10):884~887 |
英文格式: | YU Hua-chen,WEN Hong,ZHANG Yu,HU Yue-zheng,WU Jian-bin,KONG Jian-zhong.Research on the reliability of the Akagi line as a reference axis to guide for rotational alignment of the proximal tibial component in total knee arthroplasty[J].zhongguo gu shang / China J Orthop Trauma ,2015,28(10):884~887 |
|
阅读全文 下载 查看/发表评论 下载PDF阅读器 |
关闭 |
|
|
|