钢板结合异体骨板治疗股骨干内固定术后再骨折
摘要点击次数: 2377   全文下载次数: 1372   投稿时间:2007-04-28    
作者Author单位AddressE-Mail
陈长青 CHEN Chang-qing 解放军第175医院全军创伤骨科中心,福建 漳州 363000 The Center of Orthopaedics and Traumatology of PLA in 175th Hospital,Zhangzhou 363000,Fujian,China  
丁真奇 DING Zhen-qi 解放军第175医院全军创伤骨科中心,福建 漳州 363000 The Center of Orthopaedics and Traumatology of PLA in 175th Hospital,Zhangzhou 363000,Fujian,China  
郭林新 Guo Lin-xin 解放军第175医院全军创伤骨科中心,福建 漳州 363000 The Center of Orthopaedics and Traumatology of PLA in 175th Hospital,Zhangzhou 363000,Fujian,China  
练克俭 LIAN Ke-jian 解放军第175医院全军创伤骨科中心,福建 漳州 363000 The Center of Orthopaedics and Traumatology of PLA in 175th Hospital,Zhangzhou 363000,Fujian,China  
翟文亮 ZHAI Wen-liang 解放军第175医院全军创伤骨科中心,福建 漳州 363000 The Center of Orthopaedics and Traumatology of PLA in 175th Hospital,Zhangzhou 363000,Fujian,China  
期刊信息:《中国骨伤》2008年,第21卷,第2期,第111-112页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:

目的:探讨钢板结合异体骨板治疗股骨干钢板内固定术后再骨折的疗效。

方法:股骨干钢板内固定术后再骨折13例,其中男8例,女5例;年龄14~57岁,平均31.2岁。粉碎性骨折7例,斜形骨折4例,横形骨折2例。8孔股骨有限接触加压钢板5例,8孔上肢有限接触加压钢板2例,6孔股骨有限接触加压钢板2例,8孔兰氏钢板4例。钢板断裂均发生在骨折端邻近钉孔处。全部采用有限接触加压钢板(LC-DCP)加对侧异体脱蛋白骨板股骨双固定及自体髂骨移植术。

结果:13例均获得随访,时间16~40个月,平均32个月,平均骨折愈合时间为9个月,均恢复下肢行走和负重的功能。术后1年膝关节功能按Merchan标准评定:优7例,良4例,可1例,差1例,优良率84.6%(11/13).

结论:自体髂骨植骨钢板结合骨板内固定治疗股骨干再骨折效果好,可以达到骨折牢固固定的目的。
【关键词】股骨骨折  骨板  骨移植  骨折固定术,内
 
Treatment of refracture in plate-screw fixation of femoral shaft with plate and xenogenic bony plate
ABSTRACT  

Objective: To evaluate curative effect of plate and xenogenic bony plate were applied in refracture in plate-screw fixation of femoral shaft.

Methods: Thirteen cases of refracture in plate-screw fixation of femoral shaft included 8 males and 5 females,average age was 31.2 years ranging from 14 to 57. Fracture type was comminuted fracture in 7 cases,oblique fracture in 4 cases,transverse fracture in 2 cases. Fixation type used eight holes femoral LC-DCP in 5 cases,eight holes epipodite LC-DCP in 2 cases,six holes femoral LC-DCP in 2 cases,8 holes La-Plate in 4 cases. All the patients were treated by femoral LC-DCP and xenogenic bony plate.

Results: All of the patients were followed up from 16 to 40 months with average of 32 months. All cases had undergone only one operation and achieved bony union. Average time of bony union was 9 months. The lower limbs resumed walk and beared a heavy burden. According to criterion of Merchan,the results were excellent in 7 cases,good in 4,fair in 1 and poor in 1,the excellent and good rate of knee function was 84.6%(11/13)in one year after operation.

Conclusion: Treatment of refracture in plate-screw fixation of femoral shaft with armor plate and xenogenic bony plate is a reliable treatment.
KEY WORDS  Femoral fractures  Bone plates  Bone transplantation  Fracture fixation,internal
 
引用本文,请按以下格式著录参考文献:
中文格式:陈长青,丁真奇,郭林新,练克俭,翟文亮.钢板结合异体骨板治疗股骨干内固定术后再骨折[J].中国骨伤,2008,21(2):111~112