异形钢板的研制及其在肩胛骨骨折的应用 |
摘要点击次数: 2001
全文下载次数: 1331
投稿时间:2005-03-23
|
作者 | Author | 单位 | Address | E-Mail |
陈敏 |
CHEN Min |
深圳市福永人民医院骨科,广东深圳518103 |
Department of Orthopaedics,Fuyong People’s Hospital,Shenzhen 518103,Guangdong,China |
chenxiuvven055@126.com |
白龙 |
BAI Long |
深圳市福永人民医院骨科,广东深圳518103 |
Department of Orthopaedics,Fuyong People’s Hospital,Shenzhen 518103,Guangdong,China |
|
马灿泽 |
MA Can-ze |
深圳市福永人民医院骨科,广东深圳518103 |
Department of Orthopaedics,Fuyong People’s Hospital,Shenzhen 518103,Guangdong,China |
|
陈秀文 |
CHEN Xiu-wen |
深圳市福永人民医院骨科,广东深圳518103 |
Department of Orthopaedics,Fuyong People’s Hospital,Shenzhen 518103,Guangdong,China |
|
|
期刊信息:《中国骨伤》2005年,第18卷,第11期,第658-660页 |
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz |
基金项目: |
|
中文摘要:
目的:设计一种用于治疗不稳定肩胛骨骨折的新型内固定钢板,并评价其近期疗效。
方法:根据肩胛骨解剖特点以及对18例不稳定肩胛骨骨折患者的X线片和CT扫描及其手术观察,设计出适用于肩胛骨骨折内固定治疗的异形钢板。所有患者按Hardegger的骨折分型:肩胛骨体部骨折9例,外科颈骨折3例,解剖颈骨折1例,盂缘骨折3例,肩胛岗骨折2例。均行新型内固定钢板内固定。
结果:18例均获随访,随访时间6~18个月,平均12个月。按Rowe评分系统评价术后功能:优14例,良3例,可1例。
结论:本钢板设计合理,生物力学性能良好,适用于各型不稳定肩胛骨骨折。 |
【关键词】肩胛骨 骨折 骨折固定术,内 |
|
Design of plastic Ti-alloy plate with abnormal shape and using in treatment of scapula fracture |
|
ABSTRACT
Objective: To design a new type of plastic Ti-alloy plate for treatment of unstable scapula fracture and to analyze further outcomes.
Methods:A new type of plastic Ti-alloy plate for treating unstable scapula fracture was designed basing on anatomy,X-ray films,CT and surgical observation of 18 patients with scapula fracture.All fractures were classified according to Hardegger system:The scapular body fracture in 9 cases,the surgical neck fracture in 3 cases,the anatomical neck fractere in 1 case,the glenoidal lip fracture in 3 cases,the scapular spine fracture in 2 cases.All patients were treated with this new type of plate.
Results:All patients were followed up for an average time of 12 months(from 6 to 18 months).The postoperative function was evaluated according to Rowe Scoring System.The result were excellent in 14 cases,good in 3 cases,fair in 1 cases.
Conclusion:This new type of plate is characterized by reasonable design,good biomechanical behavior and could be used in various scapula fractures. |
KEY WORDS Scapula Fractures Fracture fixation,internal |
|
引用本文,请按以下格式著录参考文献: |
中文格式: | 陈敏,白龙,马灿泽,陈秀文.异形钢板的研制及其在肩胛骨骨折的应用[J].中国骨伤,2005,18(11):658~660 |
英文格式: | CHEN Min,BAI Long,MA Can-ze,CHEN Xiu-wen.Design of plastic Ti-alloy plate with abnormal shape and using in treatment of scapula fracture[J].zhongguo gu shang / China J Orthop Trauma ,2005,18(11):658~660 |
|
阅读全文 下载 查看/发表评论 下载PDF阅读器 |