不同投影方向与股骨颈前倾角测量 |
摘要点击次数: 2164
全文下载次数: 1669
投稿时间:2002-07-30
|
作者 | Author | 单位 | Address | E-Mail |
孔晓川 |
KONG Xiao-chuan |
中铁建总医院,北京 100043 |
Department of Orthopedics, Department of Radiology, General Hospital of China Railway Construction Corporation Beijing, 100043 |
|
陆应隆 |
LU Ying-long |
中铁建总医院,北京 100043 |
Department of Orthopedics, Department of Radiology, General Hospital of China Railway Construction Corporation Beijing, 100043 |
|
刘军 |
LIU Jun |
中铁建总医院,北京 100043 |
Department of Orthopedics, Department of Radiology, General Hospital of China Railway Construction Corporation Beijing, 100043 |
|
|
期刊信息:《中国骨伤》2002年,第15卷,第10期,第601-603页 |
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz |
基金项目: |
|
中文摘要:
目的:进一步探讨股骨颈前倾角测定方法及前倾角的概念。
方法:在CT上对50个股骨标本作立体成像,分别①顺股骨干纵轴、②垂直于股骨干纵轴、③垂直于股骨颈纵轴投影方向下测量股骨颈轴线与股骨冠状面夹角。其中①定名为前倾角,②定名为前屈角,③定名为冠面角。对三组数据作统计分析。
结果: 前倾角为3°~34°,平均13.42°;前屈角为7°~35°,平均17.68°;冠面角2°~31°,平均9.92°。3组数据中,任意两组之间分别呈明显的正相关关系。
结论: 不同投照方向下,股骨颈轴线与股骨冠状面夹角有差异,但相关关系密切,可互相推算。 |
【关键词】体层摄影术 X线计算机 股骨颈 摄影测量法 |
|
Investigation of the method of measurement of anteversion angle of the femoral neck and the concept of an-terversion angle |
|
ABSTRACT
Objective:To investigate the conception and the method of measurement of the femoral antever-sion angle using computerized tomography
Methods:Three-dimensional images of 50 specimens of human femur specimens were made with CT in three different projecting positions in the coronal plane, ①perpendicular to the vertical axis of the femur,②perpendicular to the longitudinal axis of the femoral neck,③the angle of intersection of the axis of the femoral neck and the coronal section of the femur was measured in the direction of projection. The measurement ①was named the anteversion angle,②was named the anteflexion anlge and ③the angle on the coronal section. Statistical analysis was performed to the data of the groups of measurements.
Results:① the range of anteversion angle was 3°-34° with an average of 13.42°;② the anteflexion angle ranged 17°- 35° with an average of 17.68°;and the angle of the coronal section ranged 2°-31° with an average of 9.92°. A remarkable positive correlation was seen among the data of any two groups.
Conclusion:Under different projecting directions there is a difference of the angle of intersection between the axis of the femoral neck the coronal section of the femur, however,they are closely rekted and can be calculated one with the other. |
KEY WORDS Tomography,x-ray computed Femur neck Photogrammetry |
|
引用本文,请按以下格式著录参考文献: |
中文格式: | 孔晓川,陆应隆,刘军.不同投影方向与股骨颈前倾角测量[J].中国骨伤,2002,15(10):601~603 |
英文格式: | KONG Xiao-chuan,LU Ying-long,LIU Jun.Investigation of the method of measurement of anteversion angle of the femoral neck and the concept of an-terversion angle[J].zhongguo gu shang / China J Orthop Trauma ,2002,15(10):601~603 |
|
阅读全文 下载 查看/发表评论 下载PDF阅读器 |