抗应力遮挡内固定钢板的有限元分析
摘要点击次数: 2214   全文下载次数: 1578   投稿时间:1999-11-05    
作者Author单位AddressE-Mail
王志彬 WANG Zhi bin 天津市中西医结合骨科研究所,天津300211 Orthopaedic Institute of Integrated Traditional Chinese and Western Medicine Tianjing,300211  
李林安 LI Lin an 天津大学,天津  
辛景义 XIN Jing yi 天津市中西医结合骨科研究所,天津300211 Orthopaedic Institute of Integrated Traditional Chinese and Western Medicine Tianjing,300211  
师宜健 天津市中西医结合骨科研究所,天津300211 Orthopaedic Institute of Integrated Traditional Chinese and Western Medicine Tianjing,300211  
邢晖 天津市中西医结合骨科研究所,天津300211 Orthopaedic Institute of Integrated Traditional Chinese and Western Medicine Tianjing,300211  
期刊信息:《中国骨伤》2000年,第13卷,第6期,第329-330页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:

目的:三维有限元法(FEM)适于内固定钢板和其改为中心外凸形状进行应力和变形分析。

方法:有限元分析中采用了1223个节点、764个八节点六面体等参元和3564个自由度。

结果:改进后的内固定钢板比原来的内固定钢板在正向力、弯矩My和Mz的作用下,柔度分别增加了6.01%、30.8%、6.12%.

结论:改进后的钢板刚度和应力替代作用被降低,符合生物力学。
【关键词】三维有限元  内固定钢板  生物力学
 
Finite elemental analysis on the anti-stress shielding effect of the internal fixation plate
ABSTRACT  

Objective:Three dimensional finite element method(FEM) is suitable for the analysis of the stress and deformation of the internal fixation plate and its modified type of the centrally convex shape.

Methods: 1223 nodes,764 8 node hexahedron isoparametric elements and 3564 freedom degrees were used in FEM analysis.

Results:In comparison with the original steel plate,the flexibility of the improved steel plate under the action of normal tensible load,y direction and z direction bending moment increased 60 1%,30 8% and 61 2% respectively.

Conclusion: Both the rigidity and the role of stress shielding decrease.The data demonstrates that this improved steel plate meets the demand of biomechanics.
KEY WORDS  Finite element method  Internal fixation steel plate  Biomechanics
 
引用本文,请按以下格式著录参考文献:
中文格式:王志彬,李林安,辛景义,师宜健,邢晖.抗应力遮挡内固定钢板的有限元分析[J].中国骨伤,2000,13(6):329~330
英文格式:WANG Zhi bin,LI Lin an,XIN Jing yi.Finite elemental analysis on the anti-stress shielding effect of the internal fixation plate[J].zhongguo gu shang / China J Orthop Trauma ,2000,13(6):329~330
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com