外固定器牵拉腰椎对马尾诱发电位及功能的影响
摘要点击次数: 1782   全文下载次数: 1140   投稿时间:1996-09-10  修订日期:1997-07-24  
作者Author单位AddressE-Mail
贺西京 He Xijing 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
陈君长 Chen Junchang 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
李辉 Li Hui 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
赵龙柱 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
常浩胜 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
李国庆 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
李浩鹏 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
史明启 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
杨哲 西安医科大学第二附属医院,710004 The Second Teaching Hospital of Xi'an Medical University (710004)  
期刊信息:《中国骨伤》1998年,第11卷,第1期,第12-15页
DOI:doi:10.3969/j.issn.1003-0034.yyyy.nn.zzz
基金项目:
中文摘要:为研究马尾神经对牵拉损伤的耐受极限及其在不同强度损伤下的变化过程,作者设计了动物马尾神经牵拉损伤的模型。手术将家犬L3、4椎骨间连接的韧带及椎间盘彻底松解,并在L2、L3、L4及L5椎体中各穿针一枚,连接外固定器。用外固定器撑大L3、4,椎骨间隙,于不同的牵拉强度和时间,检测动物马尾诱发电位、下肢疼痛反射和肌力。实验发现,急性2cm牵拉损伤可引起马尾诱发电位波形降低和畸变;立即去除牵拉损伤力,马尾诱发电位波形迅速恢复正常,次日动物肌力和疼痛反射恢复正常。但持久的2cm牵拉损伤,则造成持续的马尾诱发电位降低、畸变和运动、痛觉障碍。将牵拉损伤长度增加到3cm、4cm,则见到马尾诱发电位波形进一步降低、畸变,最后消失。由此可见椎骨间分离移位,可造成椎管内神经根牵拉损伤,使马尾诱发电位波幅降低或消失,并产生运动、痛觉障碍。轻度牵拉损伤引起的神经功能障碍是可以恢复的。但严重的牵拉损伤则引起不可逆转的神经功能障碍或丧失。
【关键词】马尾诱发电位  外固定器  腰椎
 
The SEP and Functional Changes of Cauda Equina Effected by External Fixator Traction in Lumbar Area
ABSTRACT  In order to study the endurance and the changing process of cauda equina under tractive trauma, the animal model of tractive trauma was designed. The ligament and disc between the 3rd and 4th lumbar vertebra were loosened or incised. At same time, the nails 4mm in diameter were drilled into L2, L3, L4, L5 vertebral body respectively and the other ends of nails were fixed with the external fixator. The gap between L3 and L4 was enlarged by external fixator traction. In different length and duration of traction, the CESEP and the pain reflex and muscular power of the posterior limbs were examined. The experimental results were shown as follows: (1) Acute traction 2cm in length can lower the amplitude of CESEP; as the traction was removed immediately, the lowered amplitude of CESEP was recovered very quickly, and on the next day, the pain reflex and muscular power were recovered ; (2) The 2cm continuous traction resulted in permanent low of CESEP and disability of movement and pain; (3) As the length of traction was increased to 3cm and 4cm, the amplitude and,form of CESEP became more abnormal, and at last it vanished. The results showed that separated displacement of the lumbar vertebras can result in the tractive trauma of cauda equina and thus the amplitude of CESEP is lowered or vanished and the pain reflex and muscular power is abnormal. As the tractive trauma is light, the nerve function can be recovered after removing tracting force ; as the tractive trauma is serious, the disability of nerve function will be irreversible.
KEY WORDS  CESEP External fixator  Lumbar vertebra
 
引用本文,请按以下格式著录参考文献:
中文格式:贺西京,陈君长,李辉,赵龙柱,常浩胜,李国庆,李浩鹏,史明启,杨哲.外固定器牵拉腰椎对马尾诱发电位及功能的影响[J].中国骨伤,1998,11(1):12~15
英文格式:He Xijing,Chen Junchang,Li Hui.The SEP and Functional Changes of Cauda Equina Effected by External Fixator Traction in Lumbar Area[J].zhongguo gu shang / China J Orthop Trauma ,1998,11(1):12~15
阅读全文  下载  查看/发表评论  下载PDF阅读器
关闭




版权所有:《中国骨伤》杂志社京ICP备12048066号-2  版权声明
地址:北京市东直门内南小街甲16号,100700
电话:010-64089487 传真:010-64089792 Email:zggszz@sina.com

京公网安备 11010102004237号